3.4 Cable specificationsPEBB 1(Master) PEBB 2 PEBB 3Table 7CableMainsMotorControlCable specificationsCable specificationPower cable suitable for fixed installation for thevoltage used.Symmetrical three conductor cable withconcentric protection (PE) wire or a fourconductor cable with compact low-impedanceconcentric shield for the voltage used.Control cable with low-impedance shield,screened.3.5 Stripping lengthsFig. 29 indicates the recommended stripping lengths formotor and mains cables.Table 8Stripping lengths for mains and motor cablesMains cablesMotor cablesL1, L2, L3 U, V, WFig. 28 IP20 module size H/H69 with qty 3 x 3 Mains cablesand qty 3 x 3 motor cables.ModelMains cablea(mm)b(mm)a(mm)Motor cableb(mm)c(mm)003-018 90 10 90 10 20026–046 150 14 150 14 20061–074 110 17 110 17 34090-175 160 16 160 16 41<strong>FDU</strong>48-210–250<strong>FDU</strong>69-090-175170 24 170 24 46MainsMotorFig. 29 Stripping lengths for cables(06-F45-cables only)20 Installation <strong>Emotron</strong> AB 01-4428-01r3