7.6 Pump function7.6.1 IntroductionA maximum of 4 pumps can be controlled with the standard<strong>FDU</strong> <strong>AC</strong> <strong>drive</strong>.If I/O Board options are installed, a maximum of 7 pumpscan be controlled. The I/O Board can also be used as a generalextended I/O.The Pump Control function is used to control a number of<strong>drive</strong>s (pumps, fans, etc., with a maximum of 3 additional<strong>drive</strong>s per I/O-board connected) of which one is always<strong>drive</strong>n by the <strong>FDU</strong>. Other names for this kind of controllersare 'Cascade controller' or 'Hydrophore controller'.Depending on the flow, pressure or temperature, additionalpumps can be activated via the appropriate signals by theoutput relays of the <strong>FDU</strong> and/or the I/O Board. The systemis developed in such a way that one <strong>FDU</strong> will be the masterof the system.Select relay on the control board or on an option board. Therelays are set to functions for controlling pumps. In the picturesin this section, the relays are named R:Function, e.g.R:SlavePump1, which means a relay on the control board oron a option board set to function SlavePump1.PMP1 P2 P3 P4 P5 P6All additional pumps can be activated via an <strong>AC</strong> <strong>drive</strong>, softstarter, Y/ or D.O.L. switches.SetPRESSUREFeedbackPRESSURE<strong>FDU</strong>R:SlavePump1MASTERR:SlavePump2AnInR:SlavePump3PIDAnInPMR:SlavePump4R:SlavePump5R:SlavePump6Pressure4321P1 P2 P3 P4 P5 P6PowerFlowFig. 48 Pressure control with pump control option(50-PC-2_1)Pumps in parallel will operate as a flow controller, See Fig.47.Pumps in series will operate as a pressure controller see Fig.48. The basic control principle is shown in Fig. 42.Set FLOWFeedbackFLOW<strong>FDU</strong>MASTERAnInPIDAnInR:SlavePump1R:SlavePump2R:SlavePump3R:SlavePump4R:SlavePump5R:SlavePump6NOTE: Read this instruction manual carefully beforecommencing installation, connecting or working withthe <strong>AC</strong> <strong>drive</strong> with Pump Control option.FREQUENCY (master pump P)Add pumpPressureStop pumpPower1 2 3 4Flow(50-PC-1_1)P=onP1=on P2=on P3=on P4=on P5=on P6=onFLOW /PRESSUREFig. 47 Flow control with pump control optionFLOW /PRESSURETIM E(50-PC-3_1)Fig. 49 Basic Control principle42 Main Features <strong>Emotron</strong> AB 01-4428-01r3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!