12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SIMATIC S7-300Central processing units© <strong>Siemens</strong> AG 2010St<strong>and</strong>ard CPUs5■ Technical specifications (continued)6ES7 312-1AE14-0AB06ES7 314-1AG14-0AB06ES7 315-2AH14-0AB06ES7 315-2EH14-0AB06ES7 317-2EK14-0AB0Product-type designation CPU 312 CPU 314 CPU 315-2 DP CPU 315-2 PN/DP CPU 317-2 PN/DPS7 communication• supported Yes Yes Yes Yes YesS5-compatiblecommunication• supportedYes; via CP <strong>and</strong>loadable FCYes; via CP <strong>and</strong>loadable FCYes; via CP <strong>and</strong>loadable FCYes; via CP <strong>and</strong>loadable FCYes; via CP <strong>and</strong>loadable FCWeb server• Web serverYes;Read-only functionYes;Read-only function• Number of HTTP clients 5 5Open IE communication• TCP/IPYes; via integratedPROFINET interface<strong>and</strong> loadable FBsYes; via integratedPROFINET interface<strong>and</strong> loadable FBs- Number of connections,max.8 16• ISO-on-TCP (RFC1006)Yes; via integratedPROFINET interface<strong>and</strong> loadable FBsYes; via integratedPROFINET interface<strong>and</strong> loadable FBs- Number of connections,8 16max.- Data length, max. 32 768 byte 32 768 byte•UDPYes; via integratedPROFINET interface<strong>and</strong> loadable FBsYes; via integratedPROFINET interface<strong>and</strong> loadable FBs- Number of connections,8 16max.- Data length, max. 1 472 byte 1472byteNumber of connections• overall 6 12 16 16 32• usable <strong>for</strong> PG communication5 11 15 15 31• usable <strong>for</strong> OP communication5 11 15 15 31• usable <strong>for</strong> S7 basic communication2 8 12 14 30• usable <strong>for</strong> S7 communication14 16- reserved <strong>for</strong>0 0S7 communication- Adjustable <strong>for</strong>0 0S7 communication, min.- Adjustable <strong>for</strong>14 16S7 communication, max.• Max. total number ofinstances32 32• usable <strong>for</strong> routing X1 as MPI: max. 10;X1 as DP master:max. 24;X1 as DP slave(active): max. 14;X2 as PROFINET:max. 24PROFINET CBA (at set setpointcommunication load)• Setpoint <strong>for</strong> the CPUcommunication load• Number of remote interconnectionpartners50 % 50 %32 32X1 as MPI: max. 10;X1 as DP master:max. 24;X1 as DP slave(active): max. 14;X2 as PROFINET:max. 245/8 <strong>Siemens</strong> ST 70 N · 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!