12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SIMATIC S7-300Central processing units© <strong>Siemens</strong> AG 2010Fail-safe CPUs5■ Technical specifications (continued)6ES7 315-6FF04-0AB0 6ES7 315-2FJ14-0AB0 6ES7 317-2FK14-0AB0Product-type designation CPU 315F-2 DP CPU 315F-2 PN/DP CPU 317F-2 PN/DPStatus block Yes; Up to 2 simultaneously Yes; Up to 2 simultaneously Yes; Up to 2 simultaneouslySingle step Yes Yes YesNumber of breakpoints 4 4 4Diagnostic buffer• present Yes Yes Yes• Number of entries, max. 500 500 500- can be set No No No- Of which powerfail-proof 100; Only the last 100 entries areretained100; Only the last 100 entries areretained100; Only the last 100 entries areretained• Maximum number of entries that can be readin RUN- adjustable Yes; from 10 to 499 Yes; from 10 to 499 Yes; from 10 to 499- default 10 10 10Service data• can be read out Yes YesMonitoring functionsStatus LEDs Yes Yes YesCommunication functionsPG/OP communication Yes Yes YesData record routing Yes Yes YesRouting Yes; Max. 4 Yes YesGlobal data communication• supported Yes Yes Yes• Size of GD packets, max. 22 byte 22 byte 22 byteS7 basic communication• supported Yes Yes YesS7 communication• supported Yes Yes YesS5-compatible communication• supported Yes; via CP <strong>and</strong> loadable FC Yes; via CP <strong>and</strong> loadable FC Yes; via CP <strong>and</strong> loadable FCWeb server• Web server Yes; Read-only function Yes; Read-only function• Number of HTTP clients 5 5Open IE communication• TCP/IPYes; via integrated PROFINETinterface <strong>and</strong> loadable FBsYes; via integrated PROFINETinterface <strong>and</strong> loadable FBs- Number of connections, max. 8 16• ISO-on-TCP (RFC1006)Yes; via integrated PROFINETinterface <strong>and</strong> loadable FBsYes; via integrated PROFINETinterface <strong>and</strong> loadable FBs- Number of connections, max. 8 16- Data length, max. 32 768 byte 32 768 byte•UDPYes; via integrated PROFINETinterface <strong>and</strong> loadable FBsYes; via integrated PROFINETinterface <strong>and</strong> loadable FBs- Number of connections, max. 8 16- Data length, max. 1 472 byte 1472byteNumber of connections• overall 16 16 32• usable <strong>for</strong> PG communication 15 15 31• usable <strong>for</strong> OP communication 15 15 31• usable <strong>for</strong> S7 basic communication 12 14 30• usable <strong>for</strong> S7 communication 14 16- reserved <strong>for</strong> S7 communication 0 0- Adjustable <strong>for</strong> S7 communication, min. 0 0- Adjustable <strong>for</strong> S7 communication, max. 14 165/22 <strong>Siemens</strong> ST 70 N · 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!