12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© <strong>Siemens</strong> AG 2010SIMATIC S7-300Central processing unitsFail-safe CPUs■ Overview CPU 315F-2 DP■ Overview CPU 315F-2 PN/DP5• Based on the SIMATIC CPU 315-2 DP• For setting up a fail-safe automation system in plants withincreased safety requirements• Complies with safety requirements up to SIL 3 according toIEC 61508 <strong>and</strong> up to Cat. 4 according to EN 954-1• Distributed fail-safe I/O modules can be connected throughthe integral PROFIBUS DP interface (PROFIsafe)• Fail-safe I/O modules of the ET 200M range can also becentrally connected• Central <strong>and</strong> distributed use of st<strong>and</strong>ard modules <strong>for</strong> nonsafety-oriented applicationsSIMATIC <strong>Micro</strong> Memory Card required <strong>for</strong> operation of CPU.• Based on CPU 315-2 PN/DP• The CPU with medium-sized program memory <strong>and</strong> quantitystructures <strong>for</strong> setting up a fail-safe automation system in plantswith increased safety requirements• Complies with safety requirements up to SIL 3 according toIEC 61508, PL e according to ISO 13849, <strong>and</strong> up to Cat. 4according to EN 954-1• Fail-safe I/O modules in distributed stations can be connectedthrough the integrated PROFINET interface (PROFIsafe)<strong>and</strong>/or through the integrated PROFIBUS DP interface(PROFIsafe);• Fail-safe I/O modules of the ET 200M range can also becentrally connected• Central <strong>and</strong> distributed use of st<strong>and</strong>ard modules <strong>for</strong> nonsafety-relevant applications• Component Based <strong>Automation</strong> (CBA) on PROFINET• PROFINET IO Controller <strong>for</strong> operating distributed I/O onPROFINET• PROFINET interface with 2-port switch• PROFINET proxy <strong>for</strong> intelligent devices on PROFIBUS DP inComponent Based <strong>Automation</strong> (CBA)SIMATIC <strong>Micro</strong> Memory Card required <strong>for</strong> operation of CPU.<strong>Siemens</strong> ST 70 N · 20105/17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!