© <strong>Siemens</strong> AG 2010SIMATIC S7-300Central processing unitsFail-safe CPUs■ Technical specifications (continued)6ES7 315-6FF04-0AB0 6ES7 315-2FJ14-0AB0 6ES7 317-2FK14-0AB0Product-type designation CPU 315F-2 DP CPU 315F-2 PN/DP CPU 317F-2 PN/DPNumber of connections• Max. total number of instances 32 32• usable <strong>for</strong> routing X1 as MPI: max. 10;X1 as DP master: max. 24;X1 as DP slave (active): max. 14;X2 as PROFINET: max. 24X1 as MPI: max. 10;X1 as DP master: max. 24;X1 as DP slave (active): max. 14;X2 as PROFINET: max. 24PROFINET CBA (at set setpoint communicationload)• Setpoint <strong>for</strong> the CPU communication load 50 % 50 %• Number of remote interconnection partners 32 32• Number of functions, master/slave 30 30• Total of all Master/Slave connections 1 000 1000• Data length of all incoming connections4 000 byte 4000bytemaster/slave, max.• Data length of all outgoing connections4 000 byte 4000bytemaster/slave, max.• Number of device-internal <strong>and</strong> PROFIBUS500 500interconnections• Data length of device-internal <strong>and</strong>4 000 byte 4000bytePROFIBUS interconnections, max.• Data length per connection, max. 1 400 byte 1400byte• Remote interconnections with acyclictransmission- Sampling frequency: Sampling time, min. 500 ms 500 ms- Number of incoming interconnections 100 100- Number of outgoing interconnections 100 100- Data length of all incoming interconnections,2 000 byte 2000bytemax.- Data length of all outgoing interconnections,2 000 byte 2000bytemax.- Data length per connection, max. 1 400 byte 1400byte• Remote interconnections with cyclictransmission- Transmission frequency:10 ms 10 msTransmission interval, min.- Number of incoming interconnections 200 200- Number of outgoing interconnections 200 200- Data length of all incoming interconnections,2 000 byte 2000bytemax.- Data length of all outgoing interconnections,2 000 byte 2000bytemax.- Data length per connection, max. 450 byte 450 byte• HMI variables via PROFINET (acyclic)- Number of stations that can log on <strong>for</strong> HMI3; 2x PN OPC/1x iMap 3; 2x PN OPC/1x iMapvariables (PN OPC/iMap)- HMI variable updating 500 ms 500 ms- Number of HMI variables 200 200- Data length of all HMI variables, max. 2 000 byte 2000byte• PROFIBUS proxy functionality- supported Yes Yes- Number of linked PROFIBUS devices 16 16- Data length per connection, max. 240 byte; Slave-dependent 240 byte; Slave-dependent1st interfaceType of interface <strong>Integrated</strong> RS 485 interface <strong>Integrated</strong> RS 485 interface <strong>Integrated</strong> RS 485 interfacePhysics RS 485 RS 485 RS 485Isolated No Yes YesPower supply to interface (15 to 30 V DC),max.200 mA 200 mA 200 mA5<strong>Siemens</strong> ST 70 N · 20105/23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!