12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Embedded/PC-based <strong>Automation</strong>PC-based ControlSIMATIC WinAC RTX© <strong>Siemens</strong> AG 20109■ Technical specifications (continued)6ES7 671-0RC07-0YA0Product type designation SIMATIC WinAC RTX 20094th interfaceType of interfaceMax. no. of simultaneously operableCPsPhysicsIsolatedautomatic detection of transmissionspeedPROFINETCP 1616 (HW release 8 or above),CP 1604 (HW release 7 or higher),integrated PN interface ofSIMATIC PC <strong>and</strong> S7-mECEthernetYesYes; 10/100 Mbit/sFunctionality• PROFINET IO Controller Yes• PROFINET CBAYes• Open IE communication Yes• Web serverNoPROFINET IO Controller• Services- PG/OP communication Yes- Routing Yes; S7 routing- S7 communication Yes- Open IE communication Yes• Transmission rate, min.100 Mbit/s• Transmission rate, max.100 Mbit/s• Total number of connectable 256IO Devices, max.• Number of IO Devices with IRT 64<strong>and</strong> the option "high flexibility",max.- of which in line, max. 32• IRT, supportedYes• Prioritized startup supported Yes- Number of IO Devices, max. 32• Activation/deactivation of YesIO Devices- Number of IO Devices that can 8be simultaneously activated/deactivated, max.• IO Devices changing during Yesoperation (partner ports),supported• Device replacement without Yesswap medium• Send clock times250 µs, 500 µs, 1 ms• Updating time 0.25...512depending on the send cycle• Address area- Inputs, max. 16 Kibyte-Outputs, max.16 Kibyte• User data per address area, max. 2kbyte- User data consistency, max. 256 byte6ES7 671-0RC07-0YA0Product type designation SIMATIC WinAC RTX 2009SIMATIC communication• PG/OP communicationYes• S7 routingYes• S7 communicationYes• Number of connections, max. 32Open IE communication• Open IE communication, Yessupported• Number of connections, max. 32• Local port numbers used at thesystem endIsochronous modeIsochronous modeNumber of DP masters withisochronous modeUser data per isochronous slave,max.equidistanceshortest clock pulseCPU/ programmingProgramming language• STEP 70, 20, 21, 25, 80, 102, 135, 161,34 962, 34 963, 34 964, 65 532,65 533, 65 534, 65 535Yes; only PROFIBUS2128 byte•LAD•FBD•STL•SCL•CFC• GRAPH• HiGraph ®Nesting levels 8User program protection/Yespassword protectionYes2.2 ms;2.2 ms without partial processimage;2.2 ms with partial process imageYes; V5.4, SP4 or higher,Engineering Tools (optional)YesYesYesYesYesYesYesSoftware libraries• Easy Motion ControlYes• Software redundancyYes; from V1.2, operation ofWinAC RTX with WinAC RTX onlyOpen Development interfaces• CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher• SMX (Shared Memory Extension) Yes; WinAC ODK V4.2 or higher- Inputs 4 Kibyte-Outputs4 Kibyte• CMI (Controller Management Yes; WinAC ODK V4.2 or higherInterface)9/32 <strong>Siemens</strong> ST 70 N · 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!