12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

© <strong>Siemens</strong> AG 2010Embedded/PC-based <strong>Automation</strong>Embedded <strong>Automation</strong>SIMATIC WinAC MP■ Technical specifications (continued)Product typedesignationFlag6ES7 671-4EE00-0YA0WinACMP 1776ES7 671-5EF01-0YA0WinACMP 2776ES7 671-7EG01-0YA0WinACMP 377• Number, max. 2 Kibyte 2 Kibyte 4 Kibyte• Retentivity available Yes Yes YesData blocks• Number, max. 512 1 024 2048• Size, max. 64 Kibyte 64 Kibyte 64 KibyteLocal data• per priority class, max. 16 384 byte;<strong>for</strong> all priorityclassesAddress areaI/O address area16 384 byte;<strong>for</strong> all priorityclasses16 384 byte;<strong>for</strong> all priorityclasses• overall 2 Kibyte 4 Kibyte 8 Kibyte•Outputs 2 Kibyte 4 Kibyte 8 KibyteProcess image• Inputs 1 Kibyte 2 Kibyte 2 Kibyte•Outputs 1 Kibyte 2 Kibyte 2 Kibyte• Inputs, adjustable 1 Kibyte 2 Kibyte 2 Kibyte• Outputs, adjustable 1 Kibyte 2 Kibyte 2 Kibyte• Inputs, default 512 byte 512 byte 512 byte• Outputs, default 512 byte 512 byte 512 byte• consistent data, max. 32 byte 32 byte 32 byteHardwareconfigurationNumber of DP masters• integrated 1 1 1Time of dayRuntime meter• Number 8 8 8•Number/0 to 7 0 to 7 0 to 7Number rangeS7 message functionsProcess diagnostic Yes Yes YesmessagesTest commissioningfunctionsStatus/control• Status/control variable Yes; Status Yes; Status Yes; Statusblocks, single blocks, single blocks, singlestep, breakpointstep, breakpointstep, breakpointForcing• Forcing No No NoDiagnostic buffer• present Yes Yes Yes• Number of entries,max.1 000;preset 1201 000;preset 1201000;preset 120- can be set Yes Yes YesProduct typedesignationCommunicationfunctionsNumber of logicalconnections (also innetwork), max.6ES7 671-4EE00-0YA0WinACMP 1776ES7 671-5EF01-0YA0WinACMP 2778 16 326ES7 671-7EG01-0YA0WinACMP 377PG/OP communication Yes Yes YesRouting Yes Yes YesGlobal data communication• supported No No NoS7 basic communication• supported No No NoS7 communication• supportedYes;PUT/GET,Yes;PUT/GET,Yes;PUT/GET,BSEND/BRCV, BSEND/BRCV, BSEND/BRCV,USEND/URCV USEND/URCV USEND/URCV• as server Yes Yes Yes• as client Yes Yes Yes• User data per job, max. 480 byte 480 byte 480 byteNumber of connections• overall 8;(max. 8 DP,restPROFINET)• usable <strong>for</strong>PG communication- reserved <strong>for</strong>PG communication• usable <strong>for</strong>OP communication- reserved <strong>for</strong>OP communication16;(max. 8 DP,restPROFINET)1 1 11 1 132;(max. 8 DP,restPROFINET)• usable <strong>for</strong> routing 6 14 301st interfaceDP master• Number of connections,4 8 8max.• Services- PG/OP communicationYes Yes Yes- Routing Yes Yes Yes- Global data communicationNo No No- S7 basic communicationNo No No- S7 communication Yes Yes Yes- Equidistance mode No No Nosupport- SYNC/FREEZE Yes Yes Yes- Activation/deactivationYes Yes Yesof DP slaves-DPV1 Yes Yes Yes• Transmission speeds,max.12 Mbit/s 12 Mbit/s 12 Mbit/s9<strong>Siemens</strong> ST 70 N · 20109/25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!