12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SIMATIC SoftwareRuntime software© <strong>Siemens</strong> AG 2010Modular PID control■ Technical specifications (continued)St<strong>and</strong>ard function blocks LAG2ND LIMALARM LIMITERStorage space requirements Load memory Work memory Load memory Work memory Load memory Work memory• FB length in the memory 690 byte 516 byte 390 byte 240 byte 262 byte 140 byte• DB length in the memory 190 byte 46 byte 152 byte 28 byte 124 byte 20 byteRuntimes in S7-300 0.88 … 1.14 ms 0.47 … 0.61 ms 0.14 … 0.17 msRuntimes in S7-400 0.04 … 0.16 ms 0.02 … 0.07 ms 0.03 … 0.01 msPLCSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSt<strong>and</strong>ard function blocks LMNGEN_C LMNGEN_S NONLINStorage space requirements Load memory Work memory Load memory Work memory Load memory Work memory• FB length in the memory 1576 byte 1280 byte 2578 byte 2152 byte 826 byte 672 byte• DB length in the memory 276 byte 80 byte 360 byte 110 byte 138 byte 18 byteRuntimes in S7-300 0.32 … 0.41 ms 1.16 … 1.47 ms 0.32 … 0.41 msRuntimes in S7-400 0.02 … 0.06 ms 0.06 … 0.18 ms 0.02 … 0.07 msPLCSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinAC7St<strong>and</strong>ard function blocks NORM OVERRIDE PARA_CTLStorage space requirements Load memory Work memory Load memory Work memory Load memory Work memory• FB length in the memory 234 byte 122 byte 362 byte 214 byte 406 byte 232 byte• DB length in the memory 130 byte 24 byte 146 byte 28 byte 234 byte 82 byteRuntimes in S7-300 0.33 … 0.43 ms 0.15 … 0.18 ms 0.12 … 0.15 msRuntimes in S7-400 0.02 … 0.07 ms 0.01 … 0.04 ms 0.01 … 0.03 msPLCSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSt<strong>and</strong>ard function blocks PID PULSEGEN RMP_SOAKStorage space requirements Load memory Work memory Load memory Work memory Load memory Work memory• FB length in the memory 1560 byte 1242 byte 1110 byte 872 byte 1706 byte 1500 byte• DB length in the memory 340 byte 98 byte 190 byte 34 byte 212 byte 62 byteRuntimes in S7-300 1.15 … 1.46 ms 0.17 … 0.20 ms 0.16 … 0.20 msRuntimes in S7-400 0.06 … 0.18 ms 0.01 … 0.05 ms 0.01 … 0.04 msPLCSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSt<strong>and</strong>ard function blocks ROC_LIM SCALE SP_GENStorage space requirements Load memory Work memory Load memory Work memory Load memory Work memory• FB length in the memory 1242 byte 980 byte 136 byte 32 byte 658 byte 484 byte• DB length in the memory 222 byte 50 byte 114 byte 16 byte 164 byte 40 byteRuntimes in S7-300 0.53 … 0.68 ms 0.10 … 0.13 ms 0.27 … 0.35 msRuntimes in S7-400 0.02 … 0.09 ms 0.01 … 0.02 ms 0.02 … 0.06 msPLCSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinACSIMATIC S7-300 (CPU 313 <strong>and</strong>higher), S7-400, WinAC7/20 <strong>Siemens</strong> ST 70 N · 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!