12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© <strong>Siemens</strong> AG 2010Embedded/PC-based <strong>Automation</strong>PC-based ControlSIMATIC WinAC RTX F■ Technical specifications (continued)6ES7 671-1RC07-0YA0Product type designation SIMATIC WinAC RTX F 2009DP master• Services-DPV0-DPV1• Transmission speeds, max.YesYes• Number of DP slaves, max. 6412 Mbit/s• Address area- Inputs, max. 16 Kibyte-Outputs, max.16 Kibyte• User data per DP slave- Inputs, max. 244 byte-Outputs, max.244 byte2nd interfaceType of interface CP 5613, CP 5613-A2, CP 5603Max. no. of simultaneously 4operable CPsPhysicsRS 485 / PROFIBUSIsolatedYesFunctionality•MPINo•DP masterYes• DP slaveNoDP master• Number of connections, max. 50• Services- PG/OP communication Yes- Routing Yes- Global data communication No- S7 basic communication No- S7 communication Yes- Equidistance mode support Yes; Only in conjunction withisochronous mode- Isochronous mode Yes- SYNC/FREEZE Yes- Activation/deactivation of DP Yesslaves- Direct data exchange (slave-toslaveYescommunication)-DPV0Yes-DPV1Yes• Transmission speeds, max. 12 Mbit/s• Number of DP slaves, max. 125• Address area- Inputs, max. 16 Kibyte-Outputs, max.16 Kibyte• User data per DP slave- Inputs, max. 244 byte-Outputs, max.244 byte3rd interfaceType of interfacePROFINETMax. no. of simultaneouslyoperable CPs1; Intel Pro/1000 (Intel 82571EB,82573L, 82574L, 82541PI;non shared IRQ required);integrated IE interfaceSIMATIC PC 4x7B, 6x7B, 8x7B<strong>and</strong> IPC4x7C6ES7 671-1RC07-0YA0Product type designation SIMATIC WinAC RTX F 2009PhysicsEthernetIsolatedYesautomatic detection of transmission Yes; 10/100 Mbit/sspeedFunctionality• PROFINET IO Controller Yes• PROFINET IO DeviceNo• PROFINET CBAYes• Open IE communication Yes• Web serverNoPROFINET IO Controller• Services- PG/OP communication Yes- Routing Yes; S7 routing- S7 communication Yes- Open IE communication Yes• Transmission speeds, min. 100 Mbit/s• Transmission rate, max.100 Mbit/s• Total number of connectable IO 128Devices, max.• IRT, supportedNo• Prioritized startup supported Yes- Number of IO Devices, max. 32• Activation/deactivation of YesIO Devices- Number of IO Devices that can 8be simultaneously activated/deactivated, max.• IO Devices changing during Yesoperation (partner ports),supported• Device replacement without Yesswap medium• Send clock times1 ms•Updating time1 - 512 ms (minimum valuedepends on communication shareset <strong>for</strong> PROFINET I/O, on thenumber of I/O devices, <strong>and</strong> on thevolume of configured user data)• Address area- Inputs, max. 16 Kibyte- Outputs, max. 16 Kibyte• User data per address area, max. 2kbyte- User data consistency, max. 256 byteSIMATIC communication• PG/OP communicationYes• S7 routingYes• S7 communicationYes• Number of connections, max. 16Open IE communication• Open IE communication, Yessupported• Number of connections, max. 329<strong>Siemens</strong> ST 70 N · 20109/37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!