12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Embedded/PC-based <strong>Automation</strong>Embedded <strong>Automation</strong>SIMATIC S7 modular embedded controller© <strong>Siemens</strong> AG 20109■ Technical specifications (continued)Product type designation6ES7 677-1DD00-0BA0SIMATIC S7-mEC,EC316ES7 677-1DD00-0BB0S7-mEC,EC31-RTX6ES7 677-1FD00-0FB0S7-mEC,EC31-RTX F6ES7 677-1DD00-0BF0S7-mEC,EC31-HMI/RTX128PT6ES7 677-1DD00-0BG0S7-mEC,EC31-HMI/RTX512PT6ES7 677-1DD00-0BH0S7-mEC,EC31-HMI/RTX2048PTCPU/ processing times<strong>for</strong> bit operations, min. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ.<strong>for</strong> fixed point arithmetic,0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ.min.<strong>for</strong> floating point arithmetic,0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ.min.Times/counters <strong>and</strong> theirretentivityS7 counter• Number 2 048 2 048 2 048 2048 2048• Retentivity- can be set Yes Yes Yes Yes Yes- lower limit 0 0 0 0 0- upper limit 2 047 2 047 2 047 2047 2047- preset 8 8 8 8 8• Counting range- can be set Yes Yes Yes Yes Yes- lower limit 0 0 0 0 0- upper limit 999 999 999 999 999IEC counter• present Yes Yes Yes Yes Yes• Type SFB SFB SFB SFB SFBS7 times• Number 2 048 2 048 2 048 2048 2048• Retentivity- can be set Yes Yes Yes Yes Yes- lower limit 0 0 0 0 0- upper limit 2 047 2 047 2 047 2047 2047• Time range- lower limit 10 ms 10 ms 10 ms 10 ms 10 ms- upper limit 9 990 s 9 990 s 9 990 s 9990s 9 990 sIEC timer• present Yes Yes Yes Yes Yes• Type SFB SFB SFB SFB SFBData areas <strong>and</strong> theirretentivityretentive data area, total 512 KB 512 KB 512 KB 512 KB 512 KBFlag• Number, max. 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte 16 Kibyte• of which retentive withoutMB 0 to MB 16383 MB 0 to MB 16383 MB 0 to MB 16383 MB 0 to MB 16383 MB 0 to MB 16383battery• Retentivity preset MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15• Number of clock memories 8 8 8 8 8Data blocks• Number, max.Max. code size<strong>and</strong> max. datasize: 4 MB eachMax. code size<strong>and</strong> max. datasize: 4 MB eachMax. code size<strong>and</strong> max. datasize: 4 MB eachMax. code size<strong>and</strong> max. datasize: 4 MB eachMax. code size<strong>and</strong> max. datasize: 4 MB each• Size, max. 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte 64 Kibyte9/4 <strong>Siemens</strong> ST 70 N · 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!