12.07.2015 Views

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

Products for Totally Integrated Automation and Micro ... - Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Embedded/PC-based <strong>Automation</strong>PC-based ControlSIMATIC WinAC RTX© <strong>Siemens</strong> AG 20109■ Technical specifications (continued)6ES7 671-0RC07-0YA0Product type designation SIMATIC WinAC RTX 2009Web server• Web serverOpen IE communication• TCP/IPYes- Number of connections, max. Dependent on interface- Data length, max. 65 534 byte• ISO-on-TCP (RFC1006)•UDPYes- Number of connections, max. Dependent on interface- Data length, max. 1 472 byteNumber of connectionsNoNo• overall 64• usable <strong>for</strong> PG communication- reserved <strong>for</strong> PG communication 1• usable <strong>for</strong> OP communication- reserved <strong>for</strong> OP communication 1PROFINET CBA (at set setpointcommunication load)• Setpoint <strong>for</strong> the20 %CPU communication load• Number of remote interconnectionpartners64• Number of functions,30master/slave• Total of all Master/Slave connections1 000• Data length of all incoming 6 800 byteconnections master/slave, max.• Data length of all outgoing 6 800 byteconnections master/slave, max.• Number of device-internal <strong>and</strong> 500PROFIBUS interconnections• Data length of device-internal <strong>and</strong> 4 000 bytePROFIBUS interconnections,max.• Data length per connection, max. 1 400 byte• Remote interconnections withacyclic transmission- Sampling frequency: Sampling 500 mstime, min.- Number of incoming interconnections100- Number of outgoing interconnections100- Data length of all incoming interconnections,max.2 000 byte- Data length of all outgoing interconnections,max.2 000 byte- Data length per connection, 1 400 bytemax.• Remote interconnections withcyclic transmission- Transmission frequency: 10 msTransmission interval, min.- Number of incoming interconnections200- Number of outgoing interconnections2006ES7 671-0RC07-0YA0Product type designation SIMATIC WinAC RTX 2009PROFINET CBA (at set setpointcommunication load)• Remote interconnections withcyclic transmission- Data length of all incoming 4 800 byteinterconnections, max.- Data length of all outgoing 4 800 byteinterconnections, max.- Data length per connection, 250 bytemax.• HMI variables via PROFINET(acyclic)- Number of stations that can 3log on <strong>for</strong> HMI variables(PN OPC/iMap)- HMI variable updating 500 ms- Number of HMI variables 200- Data length of all HMI variables, 2 000 bytemax.• PROFIBUS proxy functionality- supported Yes- Number of linked PROFIBUS 16devices- Data length per connection, 240 byte; Slave-dependentmax.1st interfaceType of interfaceCP 5611-A2, CP 5621, integratedPB interface of the SIMATIC PCMax. no. of simultaneously 1operable CPsPhysicsRS 485 / PROFIBUSIsolatedYesPower supply to interface does not exist(15 to 30 V DC), max.Functionality•MPINo• DP masterYes• DP slaveNoDP master• Number of connections, max. 8• Services- PG/OP communication Yes- Routing Yes- Global data communication No- S7 basic communication No- S7 communication Yes- Equidistance mode support Yes; Only in conjunction withisochronous mode- Isochronous mode Yes- SYNC/FREEZE Yes- Activation/deactivation of DP Yesslaves- Direct data exchange (slave-toslavecommunication)Yes-DPV0Yes-DPV1Yes• Transmission speeds, max. 12 Mbit/s• Number of DP slaves, max. 649/30 <strong>Siemens</strong> ST 70 N · 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!