SIMATIC S7-1200Digital modules© <strong>Siemens</strong> AG 2010SB 1223 digital input/output module4■ Technical specifications (continued)Product type designation SB 1223DI 2x24 V DC, DQ 2x24 V DCInput delay (<strong>for</strong> rated value of input voltage)• <strong>for</strong> st<strong>and</strong>ard inputs- parameterizable Yes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4,<strong>and</strong> 12.8 ms, selectable in groupsof four6ES7 223-0BD30-0XB0 6ES7 223-3AD30-0XB0 6ES7 223-3BD30-0XB0SB 12232xDI / 2xDQ 5 V DC 200kHzYes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4,<strong>and</strong> 12.8 ms, selectable in groupsof fourSB 12232xDI / 2xDQ 24 V DC 200kHzYes; 0.2, 0.4, 0.8, 1.6, 3.2, 6.4,<strong>and</strong> 12.8 ms, selectable in groupsof four- at "0" to "1", max. 2µs 2µs 2.5 µs- at "1" to "0", max. 10 µs• <strong>for</strong> interrupt inputs- parameterizable Yes Yes Yes• <strong>for</strong> counter/technological functions- parameterizable Yes Yes YesCable length• Cable length, shielded, max. 500 m 50 m 50 m <strong>for</strong> technological functions• Cable length unshielded, max. 300 mDigital outputsNumber of digital outputs 2 2 2• in groups of 1 1 1Short-circuit protection No No NoSwitching capacity of the outputs• with resistive load, max. 0.5 A 0.1 A 0.1 A• on lamp load, max.5WOutput voltage• Rated value (DC) 24 V 5V 24 V• <strong>for</strong> signal "0" (DC), max. 0.1 V; with 10k ohms load 0.4 V 0.1 V; with 10 kohms load• <strong>for</strong> signal "1", min. 20 V L+ (-0.5 V) 20 V• <strong>for</strong> signal "1" (DC), max.6VOutput current• <strong>for</strong> signal "1" rated value 0.5 A 0.1 A 0.1 A• <strong>for</strong> signal "1" permissible range, max.0.11 A• <strong>for</strong> signal "0" residual current, max. 10 µA 10 µALoad resistance range• upper limit 0.6 Ω 5 Ω 10 ΩCable length• Cable length, shielded, max. 500 m 50 m 50 m• Cable length unshielded, max. 150 mInterrupts/diagnostics/status in<strong>for</strong>mationAlarms•Alarms Yes Yes YesDiagnoses• Diagnostic functions Yes Yes YesDiagnostics indication LED• <strong>for</strong> status of inputs Yes Yes Yes• <strong>for</strong> status of outputs Yes Yes Yes4/58 <strong>Siemens</strong> ST 70 N · 2010

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!