12.07.2015 Views

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TeSysGV3-P/GV3-LCircuit-breakersThermal-magnetic 5.5…30 kWwith EverLink terminal blocks1234Thermal-magnetic circuit-breakers GV3-P for connection by EverLink terminal blocks (2)Control by rotary knobStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Setting range Reference400/415 V 500 V 660/690 V of thermalP Icu Ics (1) P Icu Ics (1) P Icu Ics (1) tripskW kA kW kA kW kA A5.5 100 50 7.5 12 50 11 6 50 9…13 GV3P137.5 100 50 11 12 50 15 6 50 12…18 GV3P1811 100 50 15 12 50 18.5 6 50 17…25 GV3P2515 100 50 18.5 12 50 22 6 50 23…32 GV3P3218.5 50 50 22 10 50 30 5 60 30…40 GV3P4022 50 50 30 10 50 37 5 60 37…50 GV3P5030 50 50 37 10 50 45 5 60 48…65 GV3P65(1) as % of lcuThermal-magnetic circuit-breakers GV3-P for connection by ring terminalsAdd the figure 6 to the end of the reference. Example: GV3-P13 becomes GV3-P136Thermal-magnetic circuit-breakers GV3-P for connection by only 1 EverLink terminal blockAdd the figure 1 to the end of the reference. Example: GV3P65 becomes GV3P651567Magnetic 11…30 kWwith EverLink terminal blocksMagnetic circuit-breakers GV3-L for connection by EverLink terminal blocks (2)Control by rotary knobStandard power ratings of 3-phase motors 50/60 Hz in category AC-3 Associated equipment Circuit-breaker400/415 V 500 V 690 V Thermal Short-circuitP Icu Ics P Icu Ics P Icu Ics overload protectionkW kA kW kA kW kA relay Rating A Reference11 100 50 15 12 50 18.5 6 50 LRD325 25 GV3L2515 100 50 18.5 12 50 22 6 50 LRD332 32 GV3L3218.5 50 50 22 10 50 30 5 60 LRD340 40 GV3L4022 50 50 30 10 50 45 5 60 LRD350 50 GV3L5030 50 50 37 10 50 45 5 60 LRD365 65 GV3L658Magnetic circuit-breakers GV3-L for connection by ring terminalsAdd the figure 6 to the end of the reference. Example: GV3-L25 becomes GV3-L256Magnetic circuit-breakers GV3-L for connection by only 1 EverLink terminal blockAdd the figure 1 to the end of the reference. Example: GV3L65 becomes GV3L651(2) 4 mm BTR screwAdd-on blocks and accessories (3)9Add-on blocks (front)Fault signalling contact + instantaneous auxiliary contactContact type NO (fault) + NC NO (fault) + NOReferences (4) GV-AED011 GV-AED10110Accessories Cover BusbarsTypeIP20 for lug IP20 for lug “Wide spacing” Set of 3-pole Set of 3-pole “S” form for sidetype terminalstype terminalsUL 508 type E 115 A busbars 115 A busbarsfor 2for 3by side mountedwhen used withcontactorcircuit-breakers circuit-breakers circuit-breaker/contactorReferences LAD96570 LAD96575 GV3G66 GV3G264 GV3G364 GV3S(3) Common add-on blocks and accessories GV2 / GV3, see page 5/15(4) For spring terminal version add 3 to the end of the reference. Example: GV-AED011 becomes GV-AED01135/14Other versions: please consult our Customer Care Centre.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!