12.07.2015 Views

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Safety modules for monitoringemergency stops and limit switchesNewNewMaximum safety level of the solution attained PL e / Cat. 4, SILCL 3(EN ISO 13849-1, EN/IEC 62061)Number of circuits Safety 3 N/O 3N/O 3 N/O 3 N/O 7 N/O 3N/O + 3N/Otime del.2N/O + 1N/Otime del.2N/O + 3N/Otime del.Additional 1 solid-state 1 N/C – 1 N/C 2 N/C 3 solid-state – 4 solid-state+ 4 solid-state + 4 solid-stateDisplay (number of LEDs) 2 2 3 4 4 11 3 4Width of housing 22.5 mm 22.5 mm 22.5 mm 45 mm 90 mm 45 mm 22.5 mm 45 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage (1) 24 VDC – – – – XPSAV11113P XPSABV11330P (2) –24 VAC/DC XPSAC5121P XPSAXE5120P (2) XPSAF5130P XPSAK311144P XPSAR311144P – – XPSATE5110P230 VAC – – – – – – – XPSATE3710P(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSAV11113P becomes XPSAV11113).(2) For a version with spring terminals, replace the letter P with the letter C at the end of the reference (example: XPSAXE5120P becomes XPSAXE5120C)coded magnetic switchesenabling switch1234Maximum safety level of the solution attained(EN ISO 13849-1, EN/IEC 62061)PL e / Cat. 4, SILCL 3For monitoring 2 coded magnetic 6 coded magnetic enabling switchswitches maximumswitches maximumNumber of circuits Safety 2N/O 2N/O 2N/OAdditional 2 solid-state 2 solid-state 2 solid-stateDisplay (number of LEDs) 3 15 3Width of housing 22.5 mm 45 mm 22.5 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage 24 VDC XPSDMB1132P (1) XPSDME1132P (1) XPSVC1132P (1)(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSDMB1132P becomes XPSDMB1132).567safety mats and edging8Maximum safety level of the solution attained PL d / Cat. 3, SILCL 2(EN ISO 13849-1, EN/IEC 62061)Number of circuits Safety 3N/OAdditional1N/C + 4 solid-stateDisplay (number of LEDs) 4Width of housing45 mmOptimum solutions: safety modules (for monitoring 1 safety function)Supply voltage 24 VAC/DC XPSAK311144P (1)(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSAK311144P becomes XPSAK311144).910Other versions: please consult our Customer Care Centre.9/15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!