12.07.2015 Views

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Light curtainsType 2 conforming to IEC 61496-2Light curtain functions• Auto/Manual,• Monitoring of external switching devices(EDM: External Devices Monitoring),• LED display of operating modesMaximum safety level achieved by the solutionPLc/cat2(EN ISO 13849-1)TypeMulti-beam, infrared transmissionSlim range Manual starting Automatic startingNominal sensing distance (Sn)0.3…15 mDetection capacity30 mm “hand”Number of safety circuits2 solid-state PNPResponse time (depending on model)14…24 msConnectionM12 ConnectorHeight protected (mm) 150 XUSLNG5D0150 XUSLNG5C0150300 XUSLNG5D0300 XUSLNG5C0300450 XUSLNG5D0450 XUSLNG5C0450600 XUSLNG5D0600 XUSLNG5C0600750 XUSLNG5D0750 XUSLNG5C0750900 XUSLNG5D0900 XUSLNG5C09001050 XUSLNG5D1050 XUSLNG5C10501200 XUSLNG5D1200 XUSLNG5C12001350 XUSLNG5D1350 XUSLNG5C13501500 XUSLNG5D1500 XUSLNG5C1500Accessories12345Cable length 3 m 10 m 30 mPre-wired connector for XUSLN For receiver <strong>XS</strong>ZNCR03 <strong>XS</strong>ZNCR10 <strong>XS</strong>ZNCR30(screened cable)For transmitter <strong>XS</strong>ZNCT03 <strong>XS</strong>ZNCT10 <strong>XS</strong>ZNCT30Type 2 conforming to IEC 61496-1 et 26Light curtain functions• Auto/Manual,• Monitoring of external switching devices(EDM: External Devices Monitoring),• LED display of operating modesType • Integral muting function.Maximum safety level achieved by the solution(EN ISO 13849-1, EN/IEC 62061)TypePLc/cat2, SILCL1Single-beam with infrared emission78Height protected (conforming to prEN 999)750…1200 mm (1 to 4 beams)Nominal sensing distance (Sn)8 mNumber of circuits Safety 2N/OAdditional4 solid-stateResponse time< 25 msModules (integral muting function) 24 VDC XPSCM1144P (1)Thru-beam pairs, Pre-cabled, L = 5m PNP XU2S18PP340L5 (2)axially alignedM12 connector PNP XU2S18PP340D (2)(1) For version with non removable terminal block, delete the letter P from the end of the reference. Example: XPSCM1144P becomes XPSCM1144).(2) For alignment at 90° to the mounting axes, insert the letter W in the reference before the last letter. Example: XU2S18PP340L5 becomes XU2S18PP340WL5).910Other versions: please consult our Customer Care Centre.9/25

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!