12.07.2015 Views

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1Functional safety of machinery> Approach according to EN/IEC 62061Risk estimation for SIL assignmentRisk related tothe identifiedhazardSeverity ofthe possibleharmFrequency and duration of exposureProbability of occurrence of a hazardous eventProbability of avoiding or limiting harmFrPrAvProbability ofoccurrence ofthat harm2Example of SIL assignmentThis assignment should be carried by determining the risk parameters that are shown below in an example.3ConsequencesSeverity (Se)Irreversible: death, losing an eye or arm 4Irreversible: broken limb(s), losing a finger(s)3Reversible: requiring attention from a medical practitioner 2Reversible: requiring first aid14Frequency and duration of exposure (Fr)Frequency of exposure> 10 min1 h> 1 h to 1 day55> 1 day to 2 weeks4> 2 weeks to 1 year 3> 1 year 2Probability of occurrenceVery highProbability (Pr)5Likely4Possible 3Rarely2Negligible 1Probability of a voiding or limiting harm (Av)Impossible 5Rarely 3Probable15Serial no.12HazardHazard <strong>XS</strong>e Fr Pr Av CI4 5 + 4 + 3 = 12678ConsequencesDeath, losing an eye or armPermanent, losing fingersReversible, medical attentionReversible, first aid(Se)43213-4SIL 2Class CI5-7SIL 2OM8-10 11-13 14-15SIL 2SIL 1OMSIL 3SIL 3SIL 2SIL 1OMSIL 3SIL 2SIL 1Frequency and durationFr 1 h to 1 day to 10 -8 to 10 -7 to 10 -6 to

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!