12.07.2015 Views

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PreventaDetection(1) (1)Coded magnetic technologyPlastic coded magnetic systemF11/BN2 AI1 7/GY +NOO1 4/BKI2 6/PK +NO O2 2/WHK23/BU+XCSDM3K1 6 47 3– 1 21/BN+DiagNONO8/OGEr 7/VTI1 5/GY +O1 4/BKI2 6/PK +O2 2/WHK23/BUK2 K1F12 A+K1+–XCSDM456 47 31 281Type of system SIL2/Category 3 SIL3/Category 4With integrated safety module XCSDM3 XCSDM4Switches for actuationFace to face, face to side, side to sideDegree of protectionPre-cabled: IP66 / IP67, IP69K, connector: IP67Type of contact2 solid-state output PNP/NO, 1,5 A / 24VDC (2 A up to 60°C)Rated operational characteristics Ub: 24 VDC +10% - 20%Dimensions W x D x H34 x 27 x 100 mmOperating zoneSao= 10 mm / Sar= 20 mmReferences Connection for cable L= 2m XCSDM379102 XCSDM480102for cable L= 5m XCSDM379105 XCSDM480105for cable L= 10m XCSDM379110 XCSDM480110for connector M12 XCSDM3791M12 XCSDM4801M12234Coded magnetic5(1) (1)WHBKWHBKBNBUBNBUContact(1NC+1NOstaggered)Contact(2NCstaggered)Plastic switchesPK GYPK GYBK WHBK WHBU BNBU BNContact(1NC+2NO,1NOstaggered)Contact(2NC+1NO,1NCstaggered)Rectangular Rectangular Cylindrical Rectangular Rectangular CylindricalWithout LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2)Type XCSDM coded magneticPre-cabled, L = 2 m Connector on flying lead, L = 10 cm (3)Switches for actuation Face to face, face to side, side to side Face to face Face to face, face to side, side to side Face to faceDegree of protection IP 66 + IP 67 IP 66 + IP 67Type of contact REED REEDRated operational characteristics Ue = 24 VDC, Ie = 100 mA Ue = 24 VDC, Ie = 100 mADimensions W x D x H 16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38,5 mm 16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38.5 mmOperating zone (4) Sao = 5 / Sar = 15 Sao = 8 / Sar = 20 Sao = 5 / Sar = 15 Sao = 8 / Sar = 20Switch with coded magnet 1NC+1NO staggered XCSDMC5902 XCSDMP5902 XCSDMR5902 XCSDMC590L01M8 XCSDMP590L01M12 XCSDMR590L01M122NC staggered XCSDMC7902 XCSDMR7902 XCSDMR7902 XCSDMC790L01M8 XCSDMP790L01M12 XCSDMR790L01M121NC+2NO, 1NO staggered – XCSDMP5002 – – XCSDMP500L01M12 –2NC+1NO, 1NC staggered – XCSDMP7002 – – XCSDMP700L01M12 –(1) Illustration of contacts with the magnet in front of the switch.(2) For version with LED indicator, replace the last 0 in the reference by 1 (example: XCSDMC5902 becomes XCSDMC5912).(3) For associated pre-wired female connectors, please refer to the “Safety solution” catalogue.(4) Sao: assured operating distance. Sar: assured release distance.678910Other versions: please consult our Customer Care Centre.9/23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!