TeSys UStarter-controller for 3-phase motorsSTANDARD motor starter1= +23Function characteristics, LUB… + LUCA… Maximum Power base Standard control unitmotor power Non-reversing Reversing Class 10 Setting range< 400/415 V (1) (2)- Thermal overload protection against: 0.09 kW LUB12 LU2B12pp LUCA6Xpp 0.15…0.6 Ashort-circuit, overcurrent, 0.25 kW LUB12 LU2B12pp LUCA1Xpp 0.35…1.4 Aphase failure or imbalance, 1.5 kW LUB12 LU2B12pp LUCA05pp 1.25…5 Ainsulation breaks (equipment only). 5.5 kW LUB12 LU2B12pp LUCA12pp 3…12 A- Manual reset following thermal fault. 7.5 kW LUB32 LU2B32pp LUCA18pp 4.5…18 A15 kW LUB32 LU2B32pp LUCA32pp 8…32 AADVANCED motor starter456Function characteristics, LUB… + LUCA… Maximum Power base Advanced control unitmotor power Non-reversing Class 10 Class 20 Setting range< 400/415 V (2) (3) (2)- Thermal overload protection against: 0.09 kW LUB120 LUCB6Xpp LUCD6Xpp 0.15…0.6 Ashort-circuit, overcurrent, 0.25 kW LUB120 LUCB1Xpp LUCD1Xpp 0.35…1.4 Aphase failure or imbalance, 1.5 kW LUB120 LUCB05pp LUCD05pp 1.25…5 Ainsulation breaks (equipment only). 5.5 kW LUB120 LUCB12pp LUCD12pp 3…12 A- Manual reset following thermal fault. 7.5 kW LUB320 LUCB18pp LUCD18pp 4.5…18 A- Thermal overload test function. 15 kW LUB320 LUCB32pp LUCD32pp 8…32 A(3) For single-phase-motors, replace LUCBpppp by LUCCpppp.MULTIFUNCTION motor starter789Function characteristics, LUB… + LUCA…- Thermal overload protection against:short-circuit, overcurrent,phase failure or imbalance,insulation breaks (equipment only).- Manual, automatic or remote reset,- Thermal overload test function,- Overtorque and no-load running, alarm,- Motor operation log,- Motor parameters display on LUCM.., PC or HMI,- Integrated Modbus communication.Maximum Power base Multifunction control unitmotor power Non-reversing Class 5 to 30 Setting range< 400/415 V0.09 kW LUB120 LUCM6XBL 0.15…0.6 A0.25 kW LUB120 LUCM1XBL 0.35…1.4 A1.5 kW LUB120 LUCM05BL 1.25…5 A5.5 kW LUB120 LUCM12BL 3…12 A7.5 kW LUB320 LUCM18BL 4.5…18 A15 kW LUB320 LUCM32BL 8…32 A10(1) Complete the references of the power bases according to the following table. Example: LU2B12 pp(2) Complete the references of the control units according to the following table. Example: LUCA/B/D/M6X ppStandard control circuit voltages24 V DC BL24 V AC B48 V AC / 48…72 V DC ES110…240 V AC / 110…220 V DC FU5/36Other versions: please consult our Customer Care Centre.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!