12.07.2015 Views

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

OsiSense XS - studiecd.dk

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TeSys UStarter-controller for 3-phase motorsFunction modules+=1Type of optional function Thermal Thermal fault signalling Motor loadoverload alarmindicationCompatible with LUCA NO NO NO NO NOCompatible with LUCL NO NO NO NO NOCompatible with LUCB, LUCD YES YES YES YES YESCompatible with LUCM NO NO NO NO YESOutput signal 1 NO 1 NO +1 NC 1 NC 1 NO 4…20 mAReset NA Manual Automatic or remote NAReferences LUFW10 LUFDH11 LUFDA01 LUFDA10 LUFV2Communication modules234Type of communication Modbus Modicon Profibus DP CANopen DeviceNet AS-Interface ParallelSTBwiringOnly compatible with 24 V DC control units YES YES YES YES YES YES YESLUCA..BL, LUCB..BL, LUCD..BL, LUCM..BLTransfer speed 19.2 Kbps Dpg. on NIM (1) 9.6…12 Mbps 20 K…1 Mbps 125…500 Kbaud 167 Kbps NANumber of slaves 31 per Modbus Dpg. on Network 125 per Profibus DP 128 per CANopen 63 per DeviceNet 62 per AS-Interface 8 per LU9GC02master Interface Module module module module master splitter boxPre-wired coil connection (A1 A2) LU9BN11C, LU9BN11L, LU9BN11L, LU9BN11L, LU9BN11L, LU9BN11C, LU9RxxLU9MRC LU9MRL LU9MRL LU9MRL LU9MRL LU9MRCConnecting cable to PC VW3 A8 306 Rpp LU9RCDpp, TSXPBSCApp TSXCANCpp DeviceNet XZCG0142 TSXCDPpppLU9RDDppstandardReferences LUFC033 LULC15 LULC07 LULC08 LULC09 ASILUFC51 LUFC00(1) Network Interface Module.Information carried by the Modbus, Modicon STB or CANopen busType of control unit LUCAppBL LUCBppBL, LUCDppBL LUCMppBLStart and Stop commands X X <strong>XS</strong>tarter status (ready, running, fault) X X XThermal alarm X XRemote reset via the bus X XIndication of motor load X <strong>XS</strong>ignalling and fault differentiation X XAlarms (overcurrent, …)XRemote programming and monitoring of all the functionsX“Log” functionXMonitoring functionXContact blocks56789Type of contact block Add-on AuxiliarySignalling contacts of any fault NC (95-96) NO (97-98) – – –position of control handle NO (17-18) NO (17-18) – – –2 auxiliary contacts module – – NO (33-34) NC (31-32) NC (31-32)– – NO (43-44) NO (43-44) NC (41-42)References Screw clamp terminals LUA1C11 LUA1C20 LUFN20 LUFN11 LUFN02Without connections LUA1C110 LUA1C200 – – –10Other versions: please consult our Customer Care Centre.5/37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!