- Page 1 and 2:
The essential guideof Automation& C
- Page 3 and 4:
ContentsDetectionp Photo-electric,
- Page 5 and 6:
ation and Control functionsMotion &
- Page 7 and 8:
DetectionThis document is a selecti
- Page 9 and 10:
ISO entry(to EN 50262)1Compact XCKT
- Page 11 and 12:
switchesThermoplasticroller lever p
- Page 13 and 14:
Operating heads,complete or for cus
- Page 15 and 16:
Operating heads,complete or for cus
- Page 17 and 18:
Severe duty for hoisting and materi
- Page 19 and 20:
Electronic sensors XMLF1Setting ran
- Page 21 and 22:
14 10 20 35 70 160 300 500conformin
- Page 23 and 24:
Electromechanical pressure switches
- Page 25 and 26:
1Non flush increased rangeM18 M30 M
- Page 27 and 28:
1U 40 x 40 x 117 U 26 x 26 x 13 U 4
- Page 29 and 30:
Miniature cylindrical metal (assemb
- Page 31 and 32:
PNP or NPNNO + NC Complementary out
- Page 39:
Forks with teach mode (1)1System, w
- Page 42 and 43:
OsiSense XUPhoto-electric sensors -
- Page 44 and 45:
OsiSense XUPhoto-electric sensorswi
- Page 46 and 47:
OsiSense XUPhoto-electric sensors,
- Page 50 and 51:
OsiSense XCCOpto-electronic rotary
- Page 52 and 53:
OsiSense XGRadio frequency identifi
- Page 54 and 55:
HarmonyHarmony control and signalli
- Page 56 and 57:
HarmonyXB6Pushbuttons, switches and
- Page 58 and 59:
HarmonyXB6Pushbuttons, switches and
- Page 60 and 61:
HarmonyXB4Pushbuttons, switches and
- Page 62 and 63:
HarmonyXB4Pushbuttons, switches and
- Page 64 and 65:
HarmonyXB5Pushbuttons, switches and
- Page 66 and 67:
HarmonyXB5Pushbuttons, switches and
- Page 68 and 69:
HarmonyXB7Pushbuttons, switches and
- Page 70 and 71:
Harmony9001K/SKPushbuttons, switche
- Page 72 and 73:
Harmony9001K/SKPushbuttons, switche
- Page 74 and 75:
HarmonyK seriesCam switches12 and 2
- Page 76 and 77:
HarmonyXVCMonolithic tower lightsØ
- Page 78 and 79:
HarmonyXVBModular tower lightsØ 70
- Page 80 and 81:
HarmonyXVM / XVPModular tower light
- Page 82 and 83:
HarmonyXVRRotating mirror beaconsØ
- Page 84 and 85:
HarmonyXACPendant control stationsf
- Page 86 and 87:
MagelisSmall PanelsMagelis STO/STUw
- Page 88 and 89:
MagelisSmall PanelMagelis XBT Rwith
- Page 90 and 91:
MagelisAdvanced PanelMagelis XBT GT
- Page 92 and 93:
MagelisAdvanced PanelMagelis XBT GH
- Page 94 and 95:
MagelisAll in OneHMI ControllersMag
- Page 96 and 97:
MagelisBOXEmbedded BOX and PC BOXMa
- Page 98 and 99:
Vijeo Designer* Available with Vije
- Page 100 and 101:
ZelioDesigned for hard-wired logic
- Page 102 and 103:
Zelio RelayElectromechanical plug-i
- Page 104 and 105:
Zelio RelayElectromechanical plug-i
- Page 106 and 107:
Zelio ControlRelays3-phase monitori
- Page 108 and 109:
Zelio ControlRelaysLift / Pump / Mo
- Page 110 and 111:
Zelio ControlMeasurement and contro
- Page 112 and 113:
Zelio TimeTiming relaysModular time
- Page 114 and 115:
Zelio AnalogAnalog InterfaceUnivers
- Page 116 and 117:
Zelio LogicSmart relaysCompact, SR2
- Page 118 and 119:
TwidoProgrammable controllersBases1
- Page 120 and 121:
TwidoProgrammable controllersCommun
- Page 122 and 123:
Modicon M340Programmable Automation
- Page 124 and 125:
Modicon M340Programmable Automation
- Page 126 and 127:
Modicon M340Programmable Automation
- Page 128 and 129:
Modicon M340Programmable Automation
- Page 130 and 131:
Modicon PremiumProgrammable Automat
- Page 132 and 133:
Modicon PremiumProgrammable Automat
- Page 134 and 135:
Modicon PremiumProgrammable Automat
- Page 136 and 137:
Modicon PremiumProgrammable Automat
- Page 138 and 139:
Modicon QuantumProgrammable Automat
- Page 140 and 141:
Modicon QuantumProgrammable Automat
- Page 142 and 143:
Modicon QuantumProgrammable Automat
- Page 144 and 145:
Modicon QuantumProgrammable Automat
- Page 146 and 147:
Automation systemsUnity Pro, a SoCo
- Page 148 and 149:
AutomationProgramming softwareFor M
- Page 150 and 151:
Vijeo CitectSCADA software1TypeSupe
- Page 152 and 153:
Altistart and AltivarUse Altistart
- Page 154 and 155:
1HighlightsAltivar 32More than 150
- Page 156 and 157:
Selection guideStandard drives - Lo
- Page 158 and 159:
Selection guideSpecialized drives -
- Page 160 and 161:
Altistart 010.37…15 kWSimple mach
- Page 162 and 163:
Altistart 224…400 kWSimple machin
- Page 164 and 165:
Altistart 484…1200 kWPumping and
- Page 166 and 167:
Altivar 120.18…4 kWSimple machine
- Page 168 and 169:
Altivar 3120.18…15 kWSimple indus
- Page 170 and 171:
Altivar 320.18…15 kWComplex machi
- Page 172 and 173:
Altivar 610.37…800 kWPumping and
- Page 174 and 175:
Altivar 610.37…800 kWPumping and
- Page 176 and 177:
Altivar 61 Plus90…2400 kWPumping
- Page 178 and 179:
Altivar 610.37…2400 kWPumping and
- Page 180 and 181:
Altivar 710.37…630 kWComplex, hig
- Page 182 and 183:
Altivar 710.75…75 kWComplex, high
- Page 184 and 185:
Altivar 71Q90…630 kWComplex, high
- Page 186 and 187:
Altivar 71 Plus90…2000 kWComplex,
- Page 188 and 189:
Altivar 710.37…2000 kWComplex, hi
- Page 190 and 191:
AccessoriesOptionsSelection guideFo
- Page 192 and 193:
Selection guideC Applications :Lexi
- Page 194 and 195:
Selection guideC Applications :Lexi
- Page 196 and 197:
Lexium 32Motion controlLexium 32 Se
- Page 198 and 199:
Lexium 32Lexium 32 motion controlSe
- Page 200 and 201:
Lexium 32Lexium 32 motion controlSe
- Page 202 and 203:
Lexium 32Motion ControlConfiguratio
- Page 204 and 205:
Lexium SDpMotion ControlStepper dri
- Page 206 and 207:
Lexium ILA/ILE/ILSMotion ControlLex
- Page 208 and 209:
Lexium Linear MotionMotion ControlL
- Page 210 and 211:
TeSysProtect your machines and inst
- Page 212 and 213:
TeSys KContactors0.06…5.5 kW1234C
- Page 214 and 215:
TeSys DContactors0.06…75 kW12345C
- Page 216 and 217:
TeSys DContactorsAuxiliary contacts
- Page 218 and 219:
TeSys FContactors90…450 kW1234Rat
- Page 220 and 221:
TeSys BContactors400…900 kW1234Ra
- Page 222 and 223:
TeSysGV2-ME, GV2-PThermal-magnetic
- Page 224 and 225:
TeSysGV3-P/GV3-LCircuit-breakersThe
- Page 226 and 227:
TeSysGV7-RThermal-magnetic circuit-
- Page 228 and 229:
TeSysGV3-METhermal-magnetic circuit
- Page 230 and 231:
TeSys DFFuse carriers0…125 A1Type
- Page 232 and 233:
TeSysLS1, GK1Fuse carriersAccessori
- Page 234 and 235:
TeSys GSSwitch-disconnector-fuses32
- Page 236 and 237:
TeSys KThermal overload relays0.11
- Page 238 and 239: TeSysLR9Electronic thermal overload
- Page 240 and 241: TeSys TMotor management systemContr
- Page 242 and 243: TeSysLT3, LT6Electronic protection
- Page 244 and 245: TeSysGV2, LCCombination motor start
- Page 246 and 247: TeSys UStarter-controller for 3-pha
- Page 248 and 249: TeSysLUTMTeSys GV3LCircuit-breakers
- Page 250 and 251: TeSysEnclosed motor starters0.06…
- Page 252 and 253: TeSysQuickfitInstallation systemPre
- Page 254 and 255: ComponentsLighting applications (AC
- Page 256 and 257: ComponentsCapacitor switching0…10
- Page 258 and 259: ComponentsHeating applications and
- Page 260 and 261: ComponentsAccessories for changeove
- Page 262 and 263: PhaseoPhaseo offers universal power
- Page 264 and 265: PhaseoPower suppliesRegulated switc
- Page 266 and 267: Phaseo SlimPower suppliesFunction m
- Page 268 and 269: PhaseoTransformers1Type of transfor
- Page 270 and 271: AB1Terminal blocksSpring clamp tech
- Page 272 and 273: Modicon I/O (ex Advantys)The compac
- Page 274 and 275: Modicon OTBIP 20 distributed I/O, o
- Page 276 and 277: Modicon STBIP 20 Distributed I/O, m
- Page 278 and 279: Modicon STBIP 20 Distributed I/O, m
- Page 280 and 281: Modicon FTMIP 67 distributed I/O, m
- Page 282 and 283: Modicon MomentumDistributed I/O and
- Page 284 and 285: Modicon MomentumDistributed I/O and
- Page 286 and 287: Modicon ABE7Telefast pre-wired syst
- Page 290 and 291: ModiconAccessories for distributed
- Page 292 and 293: Modicon FactoryCastModicon FactoryC
- Page 294 and 295: ConneXiumEthernet TCP/IP, Transpare
- Page 296 and 297: ConneXiumEthernet TCP/IP, Transpare
- Page 298 and 299: ConneXiumEthernet TCP/IP, Transpare
- Page 300 and 301: ConneXiumEthernet gatewaysEthernet/
- Page 302 and 303: ConneXiumWiFi ProductsWiFi Access P
- Page 304 and 305: AS-InterfaceModicon interfaces for
- Page 306 and 307: AS-InterfaceDedicated componentsFor
- Page 308 and 309: AS-InterfaceInstallation systemMast
- Page 310 and 311: AS-InterfaceInstallation systemJump
- Page 312 and 313: OFSOPC data server software12TypeOP
- Page 314 and 315: FactoryCastFactoryCast PLCEmbedded
- Page 316 and 317: PreventaThe Preventa range enhances
- Page 318 and 319: Functional safety«Helping you to r
- Page 320 and 321: 1Functional safety of machinery> Ap
- Page 322 and 323: 1Certified solutions for the safety
- Page 324 and 325: Save cost and time with our Prevent
- Page 326 and 327: The Protect Area Design software123
- Page 328 and 329: PreventaAutomationSafety PLCsCompac
- Page 330 and 331: PreventaAutomationSafety controller
- Page 332 and 333: 1,00,80,60,40,20,0PreventaAutomatio
- Page 334 and 335: PreventaAS-Interface safety at work
- Page 336 and 337: 111222 21PreventaDetectionIllustrat
- Page 338 and 339:
PreventaDetectionLimit switchesSafe
- Page 340 and 341:
PreventaDetectionMatsSafety mats123
- Page 342 and 343:
PreventaDetectionLight curtainsType
- Page 344 and 345:
PreventaOperator dialogEmergency st
- Page 346 and 347:
PreventaOperator dialogFoot switche
- Page 348 and 349:
PreventaOperator dialogControl unit
- Page 350 and 351:
TeSysMotor controlMotor startersEnc
- Page 352 and 353:
1A reference for installations in A
- Page 354 and 355:
OsiSense XSInductive proximity sens
- Page 356 and 357:
OsiSense XSNamur inductive sensorsM
- Page 358 and 359:
OsiSense XCLimit switchesMiniature,
- Page 360 and 361:
OsiSense XCLimit switchesClassic, f
- Page 362 and 363:
OsiSense XMElectromechanical pressu
- Page 364 and 365:
HarmonyPushbuttons and mushroom hea
- Page 366 and 367:
HarmonyIlluminated pushbuttons and
- Page 368 and 369:
MagelisSmall PanelMagelis XBT Nwith
- Page 370 and 371:
MagelisAdvanced PanelMagelis XBT GT
- Page 372 and 373:
PreventaEmergency stops and foot sw
- Page 374 and 375:
Automation platformWeighing system
- Page 376:
Schneider Electric Industries SASHe