12.07.2015 Views

Direct Vent Tankless Water Heater - Alpine Home Air Products

Direct Vent Tankless Water Heater - Alpine Home Air Products

Direct Vent Tankless Water Heater - Alpine Home Air Products

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Temperature Controller InstallationIndoor models have their controller built into the front panel. A kit is available that allows the integrated controllerto be removed and used as a remote controller. Additional controllers can also be installed.Location• The controller should be out of reach of smallchildren.• Avoid locations where the controller may becomehot (near the oven or radiant heater).• Avoid locations in direct sunlight. The digitaldisplay may be difficult to read in direct sunlight.• Avoid locations where the temperature controllercould be splashed with liquids.• Do not install in locations where it can be adjustedby the public.ConfigurationsA maximum of 4 temperature controllers, includingwired and wireless, can be installed for a water heateror bank of water heaters. Controllers can only bewired in parallel. Controllers cannot be wired inseries.The 4 temperature controllers can consist of multipleMC-91’s or MC-502RC’s but only 1 BC-100V and only1 MC-100V.Any one of the 5 types of controllers can be installedby itself and still operate the water heater. Allfunctions will be available with the exception that theclock function on the BC-100V will only be available ifan MC-100V is also connected.If 4 MC-91’s are installed, simultaneously press thePriority and On/Off buttons on the fourth controlleruntil a beep sounds.The table to the right shows some of the possiblecombinations of controllers.ControllersWire controllers in parallelMC-91 + MC-91 + MCC-91 + MC-502RCMC-91 + MCC-91 + MC-502RC + MC-502RCMCC-91 + MC-502RC + BC-100V + MC-100VMC-91 + MC-502RC + BC-100V + MC-100VMC-91 + MC-91 + MC-502RC + BC-100VMC-91 + MC-502RC + MC-502RC + MC-100VCable Lengths and SizeThe cable for the temperature controller should be anon-polarized two-core cable with a minimum gaugeof 22 AWG. The maximum cable length from eachcontroller to the water heater depends on the totalnumber of wired controllers connected to the waterheater.Number of WiredControllersMaximum Cable Length for eachController to <strong>Water</strong> <strong>Heater</strong>1 328 ft (100 m)2 164 ft (50 m)3 or 4 65 ft (20 m)VB Series Indoor LS Manual 37

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!