Accessible Infusion Pump User-Interface - Biomedical Engineering ...

Accessible Infusion Pump User-Interface - Biomedical Engineering ...

Accessible Infusion Pump User-Interface - Biomedical Engineering ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

infusion pump, it may become apparent that a single board computer is abetter choice. This is limited be several factors including price and the ability ofthe single board operating system to interface with the infusion pump’sprotocols. An optimization study will be run when enough information has beengathered.SW ArchitectureOne essential requirement of the infusion pump interface is that it be easy tooperate and not intimidating. Because of this, simple and intuitive softwarearchitecture is needed. The inputs will be split into three groups. The primaryinfusion, the secondary infusion and the total volume infused will each berepresented by a different ‘window’ on the graphic user interface. Using thearrow buttons a highlighting frame will be moved clockwise or anti-clockwisearound the graphic interface, depending on which arrow button is used. Whena window is highlighted by this frame, the OK button will select it. For the primaryand secondary infusion windows, this selection will bring about a protocolthrough which to program rates and volumes to be infused, as seen in Fig.2.1.1.6. The rate will first be set digit by digit using the arrow buttons to select adigit 0-9 and the OK button to move the cursor to the next digit. After all digitsare entered, a final OK will bring about a confirmation. The user will be askedvisually and audibly if the entered information is correct. The user will then haveto actively select [YES] to confirm this by using one of the arrow buttons to movea cursor off of [NO] and onto [YES] and then pressing the OK button. If [NO] isselected, the user will be returned to the rate select screen and will be able tomodify the information. Following the entry of the rate, the volume to be infusedwill be entered in a similar fashion. Once a rate and a volume to be infused hasbeen entered, the user will be returned to the top level of the graphic userinterface where [START INFUSION] and [STOP INFUSION] are now availableoptionsIt is not yet clear whether there must always be a secondary rate and volume tobe infused set. If this turns out to be the case, then the interface will direct theuser through entering both a primary rate and volume to be infused as well as asecondary rate and volume to be infused before they will be allowed to startthe infusion. A similar software limitation can be used to ensure that the userdoes not run a secondary infusion without a primary infusion set, if this isdetermined to be a problem.15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!