12.07.2015 Views

Emotron VFX/FDU 2.0

Emotron VFX/FDU 2.0

Emotron VFX/FDU 2.0

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

100511 Toggle loop 211341LOC/REM331213241212Sub menusNEXT222Sub menusaccording to the selection in Keyboard Reference menu[369].Remote modeWhen the VSI is switched to REMOTE operation, the VSIwill be controlled according to selected control methods inthe menu’s Reference Control [214], Run/Stop Control[215] and Reset Control [216]. The actual operation statusof the VSI will reflect the status and settings of theprogrammed control selections, e.g. Start/Stop status andsettings of the programmed control selections, accelerationor deceleration speed according to the selected referencevalue in the menu Acceleration Time [331] / DecelerationTime [332].To monitor the actual Local or Remote status of the VSIcontrol, a “Loc/Rem” function is available on the DigitalOutputs or Relays. When the VSI is set to Local, the signalon the DigOut or Relay will be active high, in Remote thesignal will be inactive low. See menu Digital Outputs [540]and Relays [550].Fig. 28 Default toggle loopIndication of menus in toggle loopMenus included in the toggle loop are indicated with ain area B in the display.Loc/Rem functionThe Loc/Rem function of this key is disabled as default.Enable the function in menu [2171] and/or [2172].With the function Loc/Rem you can change between localand remote control of the VSI from the control panel. Thefunction Loc/Rem can also be changed via the DigIn, seemenu Digital inputs [520]Change control mode1. Press the Loc/Rem key for five seconds, until Local? orRemote? is displayed.2. Confirm with Enter.3. Cancel with Esc.NEXT228Local modeLocal mode is used for temporary operation. When switchedto LOCAL operation, the VSI is controlled via the definedLocal operation mode, i.e. [2171] and [2172]. The actualstatus of the VSI will not change, e.g. Run/Stop conditionsand the actual speed will remain exactly the same. When theVSI is set to Local operation, the display will show L inarea B in the display.The VSI will be started and stopped using the keys on thecontrol panel. The reference signal can be controlled usingthe + and - keys on the keyboard, when in the menu [310]T8.3.6 Function keysThe function keys operate the menus and are also used forprogramming and read-outs of all the menu settings.Table 13ENTERESCPREVNEXTFunction keysENTER key:ESCAPE key:PREVIOUS key:NEXT key:- key:+ key:Fig. 29 Menu structure- step to a lower menulevel- confirm a changedsetting- step to a highermenu level- ignore a changedsetting, withoutconfirming- step to a previousmenu within the samelevel- go to more significantdigit in edit mode- step to a next menuwithin the same level- go to less significantdigit in edit mode- decrease a value- change a selection- increase a value- change a selection30 Operation via the Control Panel <strong>Emotron</strong> AB 01-5076-01r1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!