9.1.2 2nd Line [120]Sets the content of the lower row in the menu [100]Preferred View. Same selection as in menu [110].Default:Torque9.2 Main Setup [200]The Main Setup menu contains the most important settingsto get the AFR operational and set up for the application. Itincludes different sub menus concerning the control of theunit, protection, utilities and automatic resetting of faults.This menu will instantaneously be adapted to build inoptions and show the required settings.9.2.1 Operation [210]Selections concerning the control signals and serialcommunication are described in this submenu and is used toset the AFE up for the application.Language [211]Select the language used on the LC Display. Once thelanguage is set, this selection will not be affected by the LoadDefault command.Default:EnglishEnglish 0 English selectedSvenska 1 Swedish selectedNederlands 2Dutch selectedDeutsch 3 German selectedFrançais 4 French selectedEspañol 5 Spanish selectedРуccкий 6 Russian selectedItaliano 7 Italian selectedČesky 8 Czech selected120 2nd LineStpATorqueTurkish 9 Turkish selected211 LanguageStp A EnglishReference control [214]To control the reactive power of the AFE needs a referencesignal. This reference signal can be controlled by a remotesource from the installation, the keyboard of the AFR, or byserial or fieldbus communication. Select the requiredreference control for the application in this menu.Default:Remote 0Keyboard 1Com 2KeyboardThe reference signal comes from the analogueinputs of the terminal strip (terminals1-22).Reference is set with the + and - keys onthe Control Panel. Can only be done inmenu Set/View reference [310].The reference is set via the serial communication(RS 485, Fieldbus.) See Fieldbusor RS232/485 option manual for details.NOTE: If the reference is switched from Remote toKeyboard, the last remote reference value will be thedefault value for the control panel.Run/Stop Control [215]This function is used to select the source for run and stopcommands.Default:Remote 0214 Ref ControlStpAKeyboard215 Run/Stp CtrlStpAKeyboardKeyboardThe start/stop signal comes from the digitalinputs of the terminal strip (terminals 1-22).Keyboard 1 Start and stop is set on the Control Panel.Com 2The start/stop is set via the serial communication(RS 485, Fieldbus.) See Fieldbus orRS232/485 option manual for details.34 Functional Description for AFR unit <strong>Emotron</strong> AB 01-5076-01r1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!