Series 90-70 Genius Bus Controller Manual, GFK-2017

Series 90-70 Genius Bus Controller Manual, GFK-2017

Series 90-70 Genius Bus Controller Manual, GFK-2017

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2Connecting the Serial <strong>Bus</strong>For information about bus selection and installation, you should refer to the<strong>Genius</strong> I/O System User’s <strong>Manual</strong>.Connect the bus cable to the terminal assembly on the front of the <strong>Bus</strong> <strong>Controller</strong>. Thetie–down screws can be removed to accommodate ring-type connectors. Terminaldesignations, illustrated below, are also shown on the module faceplate.The maximum exposed length of bare wires should be two inches. For addedprotection, each shield drain wire should be insulated with spaghetti tubing to preventthe Shield In and Shield Out wires from touching each other or the signal wires.INOUTSERIAL 1 SERIAL 1SERIAL 2SHIELDOUTSERIAL 2SHIELDINNOTUSEDReplacing an Older <strong>Bus</strong> <strong>Controller</strong>If this hardware (GIOC1) is being used to replace older hardware (GIOA1 or GIOB1:see markscreen on the edge of the board), the GENIUS bus connections to the <strong>Bus</strong><strong>Controller</strong> must be rewired. Refer to the wiring label inside the module cover for detalsconcerning the proper wiring of the connector. Note that GIOC1 hardware was alsoused with <strong>Genius</strong> <strong>Bus</strong> <strong>Controller</strong> versions IC697BEM731B and C.Shield In and Shield Out Connections in an Existing InstallationThe actual positions of the <strong>Bus</strong> <strong>Controller</strong>’s Shield In and Shield Out terminals arecorrectly shown above. On the faceplates of older <strong>Bus</strong> <strong>Controller</strong>s and in earlierrevisions of the documentation, these terminals are shown reversed. Regardless ofthe markings on the faceplate, all <strong>Series</strong> <strong>90</strong>-<strong>70</strong> <strong>Bus</strong> <strong>Controller</strong>s have their Shield In andShield Out terminals in the positions shown above.Because of this inconsistency, <strong>Bus</strong> <strong>Controller</strong>s in an existing installation may have theirShield In and Shield Out terminals incorrectly connected (that is, not as illustratedabove). For most applications, this should not be a problem, and rewiring is notnecessary. If noise immunity is a particular concern, however, rewiring of the Shield Inand Shield Out terminals on these older <strong>Bus</strong> <strong>Controller</strong>s is recommended.<strong>GFK</strong>-<strong>2017</strong> Chapter 2 Installation 2-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!