TotalPac®2 Dry - FIREFLEX SYSTEMS

TotalPac®2 Dry - FIREFLEX SYSTEMS

TotalPac®2 Dry - FIREFLEX SYSTEMS

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TOTALPAC2 Page 11 of 142- Skid Air Supply OptionTOTALPAC2 Integrated Fire Protection SystemWhen TotalPac2 units are provided in skid form, the airsupply is provided by the installing contractor. Preaction, dryvalve and other sprinkler systems skids using air pressure forsupervisory or releasing purposes are all provided withoutthe external supervised air supplies.The system trim includes only a connection for the air supplyincluding a ball valve, a pressure switch and a pressuregauge, adapted to the particular layout ordered. When an airpressure maintenance device is required, it shall also beprovided and installed by the contractor along with his airsupply.The skid air supply trim is factory assembled, mounted in thesystem trim and pressure tested. Skid Air Supply for sprinklers: (Refer to Figure 1)Provides only an air supervisory and shut-off trim. Usedwith the contractor provided air supply & regulation trim,mounted separate from the TOTALPAC2 trim skid. Skid Air Supply for pilot line: (Refer to Figure 2) Verysimilar to the air supply for sprinklers, it provides only anair supervisory and shut-off trim. Used with the contractorprovided air supply & regulation trim, mounted separatefrom the TOTALPAC2 trim skid.2.1 Air supply design and selection:The air supply compressor should be sized toautomatically establish the total required air pressure in 30minutes. External air supply should be provided with an airpressure maintenance device to regulate and restrict theflow of supervisory air into the sprinkler system piping.Note: External air supply MUST always be restricted toinsure that the automatic air supply cannot replace air asfast as it escapes when a sprinkler operates.Air Supply2.2 Operation.1 To Apply Air Supply:Turn on upstream air supply. Open Air shut-offvalve (E14) by placing handle in line with valve body..2 To Close Air Supply:Close Air shut-off valve (E14) (handle crossways to valvebody).3. Maintenance and inspection:- The air or nitrogen supply provided must be continuous,clean, dry and oil free.- Determine the appropriate pressure to be maintained inthe system. Refer to Table 1 or 2Important: Advise local authorities of the necessary workover the fire protection equipment. In order to avoidaccidental water release, it is considered good practice tocompletely close the main water inlet valve while doing themaintenance work.WARNING! Pressures other than the factory pressuresettings may affect the operation of the system.FM-086G-0-43E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!