TOTALPAC2 Page 5 of 12TOTALPAC2 Integrated Fire Protection SystemSystem design & Dimensional Data2- Cabinet for Remote Controlled UnitThe TOTALPAC2 unit cabinet is made of sturdy 14 gaugesteel, measuring 36" x 20" x 57" (91,4 x 50,8 x 144,8 cm) for1½", 2" & 3" systems and 46" x 24" x 57" (116,8 x 61 x 144,8cm) for 4" & 6" for 4" & 6" systems (refer to Figure 1 fordimensions).All surfaces are rust proof coated, inside and outside, withfire red, oven baked polyester powder on phosphate base.Cabinet is provided with individual access doors for thehydraulic and electrical sections and the emergency releasewith a neoprene gasket to avoid vibrations.The field wiring electrical junction boxes is integrated with thecabinet for connection of All electrical components in the trim(pressure switches, supervisory switches, etc.) are factorywired to a terminal strip (TBA) for contractors field wiring.The junction box is provided with a cover plate maintained inplace by 4 screws and contains the wiring schematic on it'sinternal face.Junction box has 4 knock-outs for contractor field wiring.Gauges to indicate air, water supply pressure and primingwater pressure are all visible through clear Lexan windows.Multiple unit installations are easily achieved by manifoldingunits together at their water inlets but drains shall remainseparate and open. Refer to Figure 3 & 4 for additionaldetails on how to pipe drains.System Size (in.)Shipping weights:Lbs.PREACTIONKg.1½" 536 2432" 561 2553" 696 3164" 776 3526" 991 450Note: Above Shipping Weights are nominal and will changedepending on configuration and options selected.IMPORTANT! TOTALPAC2 units are NOT designed to beinstalled where they will be subjected to outdoorsand/or freezing conditions. Refer to environmentaldata for additional details. Subjecting the unit toconditions outside these limitations might hamperthe normal operation of the system.Cabinet doors are provided with hinges that can easily bedisassembled on site to remove the door assemblies forservicing. The cabinet assembly is pre-assembled, prewired,and factory tested under ISO-9001 conditions (refer toFigures 1 & 2 for installation and clearances details).Note: This cabinet contains only the mechanical section ofthe TOTALPAC2 with an electrical junction box on top of thecabinet. The top electrical section is not provided since thecontrol panel is provided by others. The cabinet is Listedboth with or without the control panel section.FM-086G-0-48C

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!