<strong>Retriever</strong> <strong>IV</strong> <strong>Fraction</strong> <strong>Collector</strong>Section 3 Operating ProceduresTable 3-2 Connector Pin DescriptionPin Wire Color Use1 Red +12 Volts2 Brown External tube change input5 Yellow Tube changing event mark6 Orange External pause8 Green Earth9 White Common11 Blue Motor Stop12 Black Valve13 Violet Pause count14 Grey End of run output3.14 Connection to TRISPumpsExample:3.15 Connection toNon-Teledyne <strong>Isco</strong>PumpsThe recommended cable for stopping the TRIS pump after the<strong>Retriever</strong> <strong>IV</strong> has completed its run is P/N 68-1020-161.An alternative cable connection to allow the fractions to be collectedvolumetrically from the TRIS pump is P/N 68-1020-159.With this connection, the TRIS pump sends electronic pulsesbased upon volume displaced to the fraction collector.The TRIS pump transmits at 267 pulses (open collector transistoroutput) per 10 revolutions of its rotor assembly. Thesepulses can be counted by <strong>Isco</strong> fraction collectors to allow collectionof fractions based upon fractions of pump revolutions. Setthe count switches to the desired volume to be pumped to eachfraction collector tube (1 ml is approximately 22 counts with 1/8"ID tubing; 78 counts with 1/16" ID tubing). Allow the pump tooperate at the selected speed for approximately 30 minutes towear in the tubing. Connect the pump to the fraction collector,measure the fluid pumped, then adjust the count in the fractioncollector to the desired accuracy. This step is necessary, since theID of standard silicone tubing can vary as much as 10%.<strong>Fraction</strong>s of 5 ml are required and the pump is found to dispense1.21 ml per rotor revolutions, or 5 ml in 4.56 revolutions. At 267pulses per 10 rotor assembly revolutions, TRIS will send out 110pulses for each 5 ml pumped (22 pulses/ml with 1/8" tubing). Byprogramming the fraction collector to collect 110 units in thevolume mode, 5 ml fractions will be collected.When a non-Teledyne <strong>Isco</strong> pump is used, a cable is used tointerrupt mains power to the pump after the last tube has beenfilled. For pumps operating on 117 Vac at 1 amp or less, cable P/N68-1010-103 is used.3-11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!