13.07.2015 Views

Retriever IV Fraction Collector User Manual - Isco

Retriever IV Fraction Collector User Manual - Isco

Retriever IV Fraction Collector User Manual - Isco

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Retriever</strong> <strong>IV</strong> <strong>Fraction</strong> <strong>Collector</strong>Section 3 Operating Proceduresimately 4 seconds later. For this reason, the adapter should normallybe mounted over the rear racks of the fraction collector asshown in Figure 3-8. When using 16 mm or larger tubes, theadapter can be aligned over the front racks and adjusted so thatdrops falling from both advancement steps fall into the tubes.Using the front position is detailed in the paragraphs describingthe use of two multi-source adapters at the end of this section.The flow diverter on the adapter can be used to direct flow awayfrom the fraction collector at the end of a run. The diverter has aspring loaded trough which swings into place when it encountersa rubber stopper placed in the last rack in the run. As shown inFigure 3-8, the trough swings into place and diverts flow into awaste vessel placed beside the collector.The following procedure should be used to set up themulti-source adapter over the rear racks.1. If not already in place, install the right stainless steel columnsupport mast and tighten firmly in place.2. Slide the multi-source adapter over the mast and temporarilytighten it so it extends out the rear of the unit as picturedin Figure 3-8.3. Loosen the four small thumbscrews on the side of theadapter. Connect the tubing from the multiple sources toeach of the special tubing connectors supplied, using thetubing ferrules as described in Figure 3-1. Using the markingson the top of the multi-source adapter as a guide,install the seven or ten tubing connectors in their properpositions (for use with seven or ten tube racks, respectively)and then tighten the four small thumbscrews on theside of the adapter to hold the tubing connectors in place.4. Set the PAUSE/RUN switch in the PAUSE position. Usinga screwdriver, or other pointed tool, set the rear panelRACKS/ TUBES switch to the RACKS position.5. Depress and hold the ADVANCE switch until the fractioncollector advances to the red stop rack and then release theswitch allowing the unit to stop at the final position of thered stop rack.3-13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!