13.07.2015 Views

NEW - Gorea plus doo

NEW - Gorea plus doo

NEW - Gorea plus doo

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

www.nuncbrand.com - Always with updated informationPhysical Properties of Nunc Brand ProductsMax. Use Temp (°C)TransparencyMicrowave-ability¹Auto-clavingGasSterilization³Dry HeatRadiationDisinfectantsSpecific GravityFlexibilityPermeability Coefficientml - mmUnits: sec - cm² - cmHg x10-¹⁰N₂ O₂ CO₂ACL 121 Opaque Marginal² Yes⁴ Yes No No Yes 1.43 rigid 0.2 0.4 1.6ETFE/ 150 Transluc Yes Yes Yes Yes No Yes 1.70 rigid – – –ECTFEFEP 205 Transluc Marginal² Yes Yes Yes No Yes 2.15 excel 20 60 135HDPE 120 Transluc No No Yes No Yes Yes 0.95 rigid 3 10 45LDPE 80 Transluc Yes No Yes No Yes Yes 0.92 excel 20 60 280NYL 90 Transluc No No Yes No Yes Yes 1.13 rigid 0.3 1.0 1.8PC 135 Clear Marginal² Yes⁴ Yes No Yes Yes 1.20 rigid 3 20 85PETG 70 Clear Yes No Yes No Yes Yes 1.27 mod 0.8 1.1 4.5PFA 250 Transluc Yes Yes Yes Yes No Yes 2.15 excel – – –PMMA 50 Clear – No Yes No Yes Some 1.20 rigid – – –PP 135 Transluc Yes Yes Yes No No Yes 0.90 rigid 4 25 90PPCO 121 Transluc Marginal² Yes Yes No No Yes 0.90 mod 6 30 100PS 90 Clear No No Yes No Yes Some 1.05 rigid 3 15 75PSF 165 Clear Yes Yes Yes Yes Yes Yes 1.24 rigid 3 15 60PUR 82 Clear No No Yes No Yes Yes 1.20 excel – – –PVDF 110 Transluc – No Yes No No Yes 1.75 rigid – – –TFE 121 Opaque – Yes Yes No – Some 1.20 excel – – –TPE 260 Opaque – Yes Yes No – Some 1.20 excel – – –TPX 175 Clear Yes Yes Yes Yes No Yes 0.83 rigid 65 270 –XLPE 100 Transluc No No Yes No Yes Yes 0.93 rigid – – –TMX 150PMX 180Additional Information1 Ratings are based on 5-minute tests at 100% power (600watts) of exposed, empty labware. CAUTION: Do notexceed Max. Use Temp., above, or expose labware tochemicals where heating may cause to attack the plasticor be rapidly absorbed.2 Plastic will absorb heat.3 Sterilization:Autoclaving (121°C, 15 psi for 20 minutes) - Cleanand rinse item with distilled water before autoclaving.Certain chemicals, which have no appreciable effect onresins at room temperature, may cause deterioration atautoclaving temperatures unless removed with distilledwater beforehand. (Always completely disengage threadsbefore autoclaving).Gas - Ethylene oxide formaldehyde. Dry head (160%°C,120 minutes) Disinfectants - Benzalkonium chloride,formalin, ethanol, etc. Radiation - gamma irradiation at2.5 (Mrad) with unstabilized plastic.4 Sterilizing reduces mechanical strength. Do not usePC vessels for vacuum applications if they have beenautoclaved.ResinsThe table is meant a guideline only. The properties of the materials mayvary both due to minor differen ces in the production conditions and todifferent conditions in the testing laboratory. Therefore Nunc cannotguarantee that the specifications will always hold.All plastics have a limited tempe rature range as shown in the adjacent table.Resin Brittleness T⁰* Max. Use T⁰High density polyethylene (HDPE) -100 120Low density polyethylene (LDPE) -100 80Polycarbonate (PC) -135 135Polyethylene terephthalate copolymer (PETG) -40 70Permanox (PMX) -10 82Polypropylene Homopolymer (PP) 0 135Polypropylene Copolymer (PPCO) -40 121Polystyrene (PS) 20 90Thermanox (TMX) -60 65* The brittleness temperature is the temperature at which an item made from the resinor crack if dropped. This is not the lowest use temperature if care is exercised in use anhandling.185

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!