EDIT DEFAULTS PAGEDisplay trend graph on UUT warm-up box will make a graph appearwhen the DoTest Button is pressed on test page.The graph will show UUToutput vs. time to allow the operator to seeif the UUT has a warm-up drift, and output has been stabilized. (Thisfeature is not likely to be required if the units to be tested are normallyconnected to a power supply.)Display test results in graph will make a graph appear at the end of theautomated test. Graph will show the UUT output error seen dur<strong>ing</strong> testvs. applied pressure.Turn on excitation warn<strong>ing</strong> sett<strong>ing</strong> will make a dialog box appear onscreen anytime the excitation is about to be changed to a higher level.(This is used to help prevent damage to unit. If all units to be tested canaccept 24VDC excitation, feature will not likely be required.)Turn on miswire warn<strong>ing</strong> will make a dialog box pop up when itappears the UUT wir<strong>ing</strong> or plumb<strong>ing</strong> has been reversed, or if the UUTpressure range appears to be set incorrectly.Turn on test results save warn<strong>ing</strong> will make a dialog box appear at anypoint where unsaved test results could be deleted.<strong>Manual</strong> step-through test will stop a test in progress at each pressurepoint and require user to press ‘OK’ on pop-up dialog.Add extra digit to pressure display increases pressure resolutionshown on real-time page. Adds one digit to the end.Restore Factory Default Sett<strong>ing</strong>s resets default sett<strong>ing</strong>s to factoryprogramm<strong>ing</strong>.Edit Default AUTO-DETECT Sett<strong>ing</strong>s opens a page to access sett<strong>ing</strong>sfor AUTO-DETECT units (269, RPM). (See Diagram 19, pg. 29)Display Trend Graph on UUT Warm-upDisplay Test ResultsExcitation Sett<strong>ing</strong> Warn<strong>ing</strong>Miswire Warn<strong>ing</strong>Test Results Save Warn<strong>ing</strong><strong>Manual</strong> Step-Through TestExtra Digit ResolutionRestore Factory DefaultsOpens AUTO-DETECT Default Sett<strong>ing</strong>s PageDiagram 1828

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!