Series 5600 Outside Glazed <strong>Installation</strong> <strong>Instructions</strong>Section V: Alternate Anchorage Method (PunchedOpenings)STEP #2 Install Frame ComponentsInstall perimeter channel anchor to the head and sill with appropriate shims andanchor bolts. The channel must be set to proper benchmarks for final position of thewall. The ends of the channels should be mitered for continuity, and should abut andseal to the ends of the anchor channels at the jambs. See inset at step #3.Refer to approved shop drawings for job specific conditions, anchor bolt sizes, andlocations. Install assemblies according to approved shop drawings.Anchor bolts as required.Mitered ends atchannel anchorsPerimeter channelanchor.Shims as required.Head & Sill ConditionEFCO CORPORATION 6/2012 PART NO. YS56 Page 22 of 54