Series 5600 Outside Glazed <strong>Installation</strong> <strong>Instructions</strong>Section VII: Glazing PreparationSTEP #3 Install Glazing AdaptorsA.) Prior to installing the glazing adaptors, seal the full length of the gasketraceway with sealant.B.) Snap the glazing adaptors in place in the sealant, starting with the verticals.Allow at least 1/8” clearance from the bottom of the glazing adaptors to thetop of the joint plugs to allow for weepage.C.) Apply sealant to the ends of the horizontal adaptors prior to setting theminto position. Snap the horizontal adaptors in place between the verticaladaptors. Seal the face of the adaptor intersections with sealant. Tool allsealant joints, and remove all excess sealant.Continuously seal gasketraceway with sealant priorto installing the adaptors.Clearance requiredfor weepage.Glazing adaptorsNOTE: The vertical adaptorswill need clearance abovethe joint plugs, free fromsealant for weepage.Glazing Adaptor Cut Formula:Vertical = D.L.O. + 1”.Horizontal = D.L.O. – 1/16”EFCO CORPORATION 6/2012 PART NO. YS56 Page 32 of 54