Series 5600 Outside Glazed <strong>Installation</strong> <strong>Instructions</strong>Section VI: Perimeter Channel Splice (PunchedOpenings)STEP #1 Splice Perimeter ChannelInstall the perimeter channel to the head and sill conditions with appropriate shimsand anchor bolts. The channel must be set to proper benchmarks for the finalposition of the wall. The nominal gap for the splice joint is 3/8”. Apply bond breakertape to the splice sleeve.Anchor bolts as required.Splice sleeveBond breaker tape3/8” splice jointShim asrequired.EFCO CORPORATION 6/2012 PART NO. YS56 Page 27 of 54