Example -- A sample newdocument.ini file:<br />

[general]<br />

; allow download of an already checkout object<br />

okToDownloadAlreadyCheckedOut=true<br />

; for a newly created CAD Doc the destination folder<br />

; where the document may be moved upon checkin<br />

;DefaultDocFolder=/<br />

; set to true by default for Pro/E<br />

isModelNameUnique=true<br />

[proe]<br />

; Valid Pro/E model file name extensions.<br />

proe.files.component.ext=.prt<br />

proe.files.assembly.ext=.asm<br />

proe.files.drawing.ext=.drw<br />

proe.files.diagram.ext=.dgm<br />

proe.files.format.ext=.frm<br />

proe.files.layout.ext=.lay<br />

proe.files.manufacturing.ext=.mfg<br />

proe.files.markup.ext=.mrk<br />

proe.files.report.ext=.rep<br />

proe.files.sketch.ext=.sec<br />

;no specific extension for "other"<br />

CADComponentDocNumber=00008_comp_1.prt<br />

CADAssemblyDocNumber=00008_asm_1.asm<br />

CADDrawingDocNumber=00008_drw.drw<br />

DiagramDocNumber=00008_dgm.dgm<br />

FormatDocNumber=0008_frm.frm<br />

LayoutDocNumber=00008_lay.lay<br />

ManufacturingDocNumber=0008_mfg.mfg<br />

MarkupDocNumber=00008_mrk.mrk<br />

ReportDocNumber=00008_rep.rep<br />

SketchDocNumber=0008_sec.sec<br />

OtherDocNumber=00008_other.oth<br />

Note: The parameter isModelNameUnique=true should not be changed.<br />

Note: New document templates are specified by replacing existing *DocNumber<br />

settings with the number of your chosen template document.<br />

Overriding INI File Settings<br />

To override the default preferences of an INI file, create a user-modified version<br />

of the file in the user’s personal cabinet:<br />

Note: The following procedure applies to <strong>Windchill</strong> PDM only (user cabinets are<br />

not directly accessible in <strong>Windchill</strong> PDMLink or <strong>Windchill</strong> ProjectLink).<br />

1. Upload the selected INI file to the user’s personal cabinet, giving it a name<br />

and number as follows:<br />

The _ format of a user preference file is<br />