SECTION 2TROUBLESHOOTINGFor ducted units, the GREEN operation indicator LED (SeeFigure 3 -9) will flash if there is a problem.Refer to Table 2 -1 <strong>for</strong> diagnostic in<strong>for</strong>mation.SYMPTOM AND PROBABLE CAUSE2.1 NO POWER TO UNITPROBABLE REMEDY1. Master switch off2. Open circuit breaker3. Defective wiring4. Loose electrical connections5. Faulty switches, thermostat, or fan6. 12 VDC not connected (Ducted System)7. 12 VDC in--line fuse open (Ducted)2.2 DUCTED UNIT WILL NOT OPERATE1. Display not illuminated2. Display illuminated2.3 DUCTED UNIT WILL NOT COOL1. Green LED light flashes 5 times2. Unit cools <strong>for</strong> a few moments then stops cooling2.4 COMPRESSOR POWER SUPPLY OPEN1. Loose leads at compressor terminals2. Defective motor overload switch3. Defective capacitor4. Open compressor windings5. Seized compressor6. Capacitor incorrectly wired1. Reset master switch2. Reset circuit breaker3. Replace wiring4. Tighten connections5. Replace defective components6. Connect to 12 VDC power source7. Replace fuse1. Check 12 Volt DC in--line fuse2. Check 115 Volt AC Connections2.5 COMPRESSOR RUNS BUT CYCLES, FAN OPERATING ERRATICALLY1. Loose lead at fan motor2. Defective or burned out motor3. Outdoor air restricted or recirculating4. Overcharge or noncondensables in system5. Restricted discharge line6. Defective motor overload switch1. Check 115 volt AC power sourceMomentarily disconnect 12 VDC power sourceDisable compressor malfunction test switch.Check AMP draw.Check ∆ T2. Remove grill, verify evaporator coil probe isinserted into coil.Check AMP draw.Check ∆ TReplace unit1. Tighten leads2. Replace switch3. Replace capacitor -- Refer to Paragraph 3.6.84. Replace compressor5. Replace compressor6. Verify capacitor wiring (Refer to wiring diagram)1. Tighten lead.2. Replace motor.3. Check <strong>for</strong> dirty condenser coil, proper clearancearound unit, remove any obstructions.4. Check AMP draw5. Check <strong>for</strong> obstruction in line.Check ∆ T.Replace unit.6. Replace switch.10-092--1T--298

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!