19.08.2015 Views

SERVICE MANUAL for MODEL AirV Rooftop Air Conditioning Systems

SERVICE MANUAL for MODEL AirV Rooftop Air Conditioning Systems

SERVICE MANUAL for MODEL AirV Rooftop Air Conditioning Systems

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3.8 THERMOSTAT INSTALLATION AND START -UP INSTRUCTIONS (WALL MOUNTED)3.8.1 IntroductionThe thermostat is a wall mounted, low--voltagethermostat which maintains room temperature bycontrolling the operation of a heating and airconditioning system. Temperature and mode settingsare preserved with the power off. Refer to Figure 3--41<strong>for</strong> Cool Only wiring diagram and Figure 3--42 orFigure 3--43 <strong>for</strong> Cool/HeatCAUTIONImproper wiring or installation may damagethermostat. Wiring must con<strong>for</strong>m to localand national electrical codes.WARNINGBe<strong>for</strong>e installing thermostat, turn off allpower to unit. There may be more than onepower disconnect. Electrical shock cancause personal injury or death.3.8.2 InstallationNOTERead all instructions be<strong>for</strong>e starting the installation.NOTEThe thermostat requires no batteries. The thermostatis not a power stealing device andMUST have both R and C connected.3.8.3 Thermostat LocationThe thermostat should be mounted:Approximately 5 foot (1.5m) from the floor.Close to or in a frequently used room, preferably onan inside partitioning wall.On a section of wall without pipes or duct work.The thermostat should NOT be mounted:Close to a window, or an outside wall, or next to a doorleading to the outside.Exposed to direct light and heat from a lamp, sun, fireplace,or other temperature--radiating object whichmay cause a false reading.Close to or in direct airflow from supply registers andreturn--air grilles.In areas with poor air circulation, such as behind adoor or in an alcove.3.8.4 Install Thermostat - 12VDCa. Turn off all power to unit.b. If an existing thermostat is being replaced:1.Remove existing thermostat from wall.2.Disconnect wires from existing thermostat, one ata time. Be careful not to allow wires to fall back intothe wall.3.As each wire is disconnected, record wire colorand terminal marking.4.Discard or recycle old thermostat.NOTEMercury is a hazardous waste and must be disposedof properly.c. Separate the front and back pieces of plastic.d. Route thermostat wires through hole in back piece ofplastic. Level plastic against wall (<strong>for</strong> aesthetic valueonly -- thermostat need not be leveled <strong>for</strong> proper operation)and mark wall through 2 mounting holes.e. Drill two 3/16 inch mounting holes in wall wheremarked.NOTEMounting holes on thermostat are designed tofit on a horizontal J--Box.f. Secure back plastic to wall with 2 anchors and screwsprovided, making sure all wires extend through hole inplastic.g. Connect wires to proper terminal of the connectorblock in the front piece of plastic.h. Push any excess wire back into wall. Excess wire insidethe thermostat plastic case can interfere withproper air flow across the temperature sensor. Sealhole in wall to prevent air leaks. Leaks can effect operation.i. Snap front and back pieces of plastic together.j. Turn on power to the unit.3.9 LCD DISPLAY3.9.1 Cool Only Thermostat (Part No. 1110 -421)On power up, the LCD readout will display C (CoolOnly).3.9.2 Heat/Cool Thermostat (Part No. 1110 -420)On power up, the LCD readout will display HC (Heat/Cool).3.10 SET THERMOSTAT CONFIGURATIONWhile in configuration mode, three option choices can bemade.A - Anticipator Value Adjustmentd - Display Temperature Fahrenheit/Celsius SelectionoF - Offset Adjustment For Room Temperature3.10.1 Enter Configuration ModeEnter and hold the FAN button <strong>for</strong> approximately 10 secondsuntil room temperature disappears and the displayreads A. You are now in the configuration mode.10/093--17T--298

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!