IEC Squirrel-Cage Motors<br />

Standard motors up to frame size 315 L<br />

Special versions<br />

2<br />

Special versions<br />

Voltage<br />

code<br />

11th<br />

position<br />

of the<br />

Order No.<br />

Additional<br />

identification<br />

code<br />

-Z with<br />

order code<br />

and plain<br />

text if<br />

required<br />

Motor type frame size<br />

Self-cooled motors without external fan - Aluminium series 1LP7 and 1LP5<br />

1LP7 (aluminium)<br />

56 63 71 80 90 100 112 132 160 180 200 225 250 280 315<br />

S/M 315<br />

L<br />

1LP5 (aluminium)<br />

Voltage at 50 Hz<br />

220 VD/380 VY<br />

9 L1R ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

50 Hz output<br />

(210 ... 230 VD/360 ... 400 VY);<br />

380 VD/660 VY<br />

9 L1L ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

50 Hz output<br />

(360 ... 400 VD/625 ... 695 VY);<br />

415 VY (395 ... 435 VY); 9 L1C ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

50 Hz output 1)<br />

415 VD (395 ... 435 VD); 9 L1D ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

50 Hz output 1)<br />

400 VY (380 ... 420 VY); 9 L1A † † † † † † † † † †<br />

50 Hz output 1)<br />

400 VD (460 VD at 60 Hz) 9 L1U † † † † † † † † † †<br />

(380 ... 420 VD);<br />

50 Hz output 1)<br />

Voltage at 60 Hz<br />

220 VD/380 VY; 50 Hz output 9 L2A ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

220 VD/380 VY; 60 Hz output 9 L2B ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

380 VD/660 VY; 50 Hz output 9 L2C ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

380 VD/660 VY; 60 Hz output 9 L2D ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

440 VY; 50 Hz output 9 L2Q ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

440 VY; 60 Hz output 9 L2W ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

440 VD; 50 Hz output 9 L2R ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

440 VD; 60 Hz output 9 L2X ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

460 VY; 50 Hz output 9 L2S ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

460 VY; 60 Hz output 9 L2E † † † † † † † † † †<br />

460 VD; 50 Hz output 9 L2T ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

460 VD; 60 Hz output 9 L2F † † † † † † † † † †<br />

575 VY; 50 Hz output 9 L2U ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

575 VY; 60 Hz output 9 L2L ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

575 VD; 50 Hz output 9 L2V ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

575 VD; 60 Hz output 9 L2M ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Voltage changeover at 60 Hz<br />

230 VYY/460 VY 60 Hz; 9 L3E ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

50 Hz output, 9 main terminals<br />

and electrical design to NEMA<br />

230 VYY/460 VY 60 Hz; 9 L3F ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

60 Hz output, 9 main terminals<br />

and electrical design to NEMA<br />

230 VDD/460 VD 60 Hz; 9 L3G † † † † ✓ ✓ ✓ ✓ ✓ ✓<br />

50 Hz output, 12 main terminals<br />

and electrical design to NEMA<br />

230 VDD/460 VD 60 Hz; 9 L3H † † † † ✓ ✓ ✓ ✓ ✓ ✓<br />

60 Hz output, 12 main terminals<br />

and electrical design to NEMA<br />

Non-standard voltage and/or frequencies<br />

Standard winding<br />

9 L8Y • ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

will be stamped in accordance<br />

with order) 2)<br />

(winding according to voltage<br />

code 0, 1, 3, 5 or 6; rating plate<br />

Non-standard winding for voltages<br />

9 L1Y • ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

(voltages outside this range are<br />

available on request) 2) between 200 and 690<br />

V<br />

For legend and footnotes, see page 2/75.<br />

2/74 Siemens D 81.1 · 2006