20.09.2015 Views

Catalog

Old Catalog Motor 2006.pdf - Motology

Old Catalog Motor 2006.pdf - Motology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1<br />

IEC Squirrel-Cage Motors<br />

Introduction<br />

General technical data<br />

Shaft extension with standard dimensions, without featherkey way<br />

For motor series 1LA8, 1PQ8 and 1LL8, the standard shaft extension<br />

can be ordered with standard dimensions without a featherkey<br />

way.<br />

Order code K42<br />

Other motor series must be ordered with order code Y55.<br />

Standard shaft made of non-rusting steel<br />

For motor series 1LA5, 1LA6, 1LA7, 1LP5, 1LP7, 1PP5 and 1PP7,<br />

a standard shaft made of non-rusting steel (material X20Cr13V)<br />

can be ordered. This is only possible for shaft extensions of standard<br />

dimensions. For non-standard shaft dimensions, there will<br />

be an additional charge!<br />

Order code M65<br />

Please enquire about other non-rusting materials.<br />

Please enquire regarding motor series 1LG4 and 1LG6.<br />

Non-standard cylindrical shaft extension<br />

The non-standard cylindrical shaft extension can be used on the<br />

drive end (DE) or non-drive end (NDE). The featherkey is always<br />

supplied with it.<br />

Order code Y55<br />

When motors are ordered that have a longer or shorter shaft extension<br />

as standard, the required position and length of the<br />

featherkey way must be specified in a sketch. It must be ensured<br />

that only featherkeys in accordance with DIN 6885, Form A are<br />

permitted to be used. The location of the featherkey way is in the<br />

centre of the shaft extension and, in the case of non-standard<br />

Permissible changes to the shaft extension:<br />

Concentricity of shaft extension, coaxiality and linear movement<br />

in accordance with DIN 42955 Tolerance R for flange-mounting<br />

motors<br />

The following are specified in DIN 42955 with Tolerance N<br />

(normal) and Tolerance R (reduced):<br />

1. Concentricity tolerances for the shaft extension<br />

2. Coaxiality tolerances for the shaft extension and flange<br />

centering<br />

3. Linear movement tolerances for the shaft extension and<br />

flange surface<br />

1/56 Siemens D 81.1 · 2006<br />

motors, 5 mm from the shaft extension. The length is defined by<br />

the manufacturer normatively.<br />

Not valid for: Conical shafts, non-standard threaded journals,<br />

non-standard shaft tolerances, friction welded journals, extremely<br />

“thin” shafts, special geometry dimensions (e.g. square<br />

journals, etc.), hollow shafts.<br />

For the version “Drive-end shaft extension (DE) without<br />

featherkey way”, order code Y55 must also be used.<br />

For 1MJ motors with longer shaft extensions than standard, the<br />

maximum cantilever force must be reduced accordingly. This<br />

will ensure that the shaft does not sag more than with the standard<br />

shaft extension (please enquire).<br />

For order code Y55 and second standard shaft extension K16<br />

(see previous page):<br />

• Dimensions D and DA must be less than or equal to the inner<br />

diameter of the roller bearing (see dimension tables under<br />

“Dimensions” in the relevant chapters)<br />

• Dimensions E and EA must be smaller than or equal to 2 x<br />

length E (standard) of the shaft extension<br />

A non-standard cylindrical shaft extension can be supplied for<br />

the motor series listed in the table “Permissible changes to shaft<br />

extension” below up to the specified maximum lengths and<br />

diameters as compared to the standard shaft.<br />

It is the responsibility of the customer to ensure that the maximum<br />

cantilever forces are reduced in accordance with the nonstandard<br />

shaft extension.<br />

Motor series Frame size Number of poles Shaft extension length<br />

E in mm<br />

Shaft extension diameter<br />

D in mm<br />

Standard Up to max. Standard Up to max. 1)<br />

1LA6,<br />

56 2 ... 8 20 40 9 12<br />

1LA7,<br />

63 23 46 11<br />

1LA9,<br />

1MA6,<br />

71 30 60 14 15<br />

1MA7,<br />

80 40 80 19 20<br />

1LP7,<br />

90 50 100 24 25<br />

1PP7<br />

100 60 120 28 30<br />

112<br />

132 80 160 38 40<br />

160 110 220 42 45<br />

1LA5,<br />

1LA9,<br />

1LG4,<br />

1LG6,<br />

1MA6,<br />

1LP4,<br />

1LP5,<br />

1PP4,<br />

1PP5<br />

1LA8,<br />

1PQ8<br />

180 2 ... 8 48 48<br />

200 55 55<br />

225 2 60<br />

4...8 140 280 60<br />

250 2 70<br />

4...8 65<br />

280 2 75<br />

4 ... 8 75 80<br />

315 2 65<br />

4...8 170 340 80 90<br />

315 2 140 280 65 70<br />

4...8 170 340 85 85<br />

355 2 140 280 75 80<br />

4...8 170 340 95 95<br />

400 2 80 80<br />

4 ... 8 210 420 110 115<br />

450 2 170 340 90 90<br />

4 ... 8 210 420 120 125<br />

1)<br />

At maximum permissible diameter, a step increase in shaft diameter is not possible.<br />

The concentricity of the shaft extension, coaxiality and linear<br />

movement according to DIN 42955 Tolerance R for flangemounting<br />

motors can be ordered using order code K04.<br />

This order code can be combined for motors with deep-groove<br />

bearings of series 60.., 62.. and 63… This cannot be supplied in<br />

combination with parallel roller bearings (e.g. bearings for increased<br />

cantilever forces, order code K20), brake or encoder<br />

mounting.<br />

Concentricity of the shaft extension can be ordered according to<br />

DIN 42955 Tolerance R for types of construction without a flange<br />

with order code L39.