20.09.2015 Views

Catalog

Old Catalog Motor 2006.pdf - Motology

Old Catalog Motor 2006.pdf - Motology

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

IEC Squirrel-Cage Motors<br />

Non-standard motors frame size 315 and above<br />

Special versions<br />

3<br />

Special versions<br />

Additional Motor type frame size<br />

identification<br />

code<br />

-Z with<br />

order<br />

code and<br />

plain text if<br />

required<br />

315 355 400 450 315 355 400 450<br />

Self-ventilated motors with through ventilation for mains-fed and converter-fed operation<br />

1LL8<br />

1LL8<br />

Mains-fed operation<br />

Converter-fed operation<br />

Designs in accordance with standards and specifications<br />

Electrical according to NEMA MG1-12 D30 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Design according to UL with D31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

"Recognition Mark"<br />

VIK version K30 – – – – – – – –<br />

Canadian regulations (CSA) D40 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Designs for Zones 2 and 22 according to ATEX<br />

Design for Zone 2 for mains-fed M72 – – – – – – – –<br />

operation Ex nA II T3, EEx nA II T3<br />

to IEC/EN 60079-15<br />

Design for Zone 2 for converter-fed M73 – – – – – – – –<br />

operation, derating Ex nA II T3,<br />

EEx nA II T3 to IEC/EN 60079-15<br />

Design for Zone 22 for non-conducting<br />

M35 – – – – – – – –<br />

dust (IP55) for mains-fed<br />

operation<br />

Designs for Zone 22 for non-conducting<br />

M39 – – – – – – – –<br />

dust (IP55) for converter-fed<br />

operation<br />

Stamping of EEx nA II on VIK rating C27 – – – – – – – –<br />

plate<br />

Bearings and lubrication<br />

Measuring nipple for SPM shock G50 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

pulse measurement for bearing<br />

inspection<br />

Bearing design for increased K20 – – – – – – – –<br />

cantilever forces<br />

Balance and vibration severity<br />

Full key balancing L68 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Vibration severity level R<br />

K01 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

(valid until 11/30/2006; then vibration<br />

severity level A as standard version<br />

without order code)<br />

Vibration severity level S<br />

K02 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R.<br />

(valid until 11/30/2006; then vibration<br />

severity level B)<br />

Shaft and rotor<br />

Second standard shaft<br />

K16 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

extension 5)<br />

Shaft extension with standard<br />

dimensions, without featherkey way<br />

K42 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Non-standard cylindrical shaft<br />

extension<br />

Y55 • and<br />

identification<br />

data<br />

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Heating and ventilation<br />

Metal external fan K35 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Anti-condensation heaters for 230 V K45 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Anti-condensation heaters for 115 V K46 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Sheet metal fan cover L36 p p p p p p p p<br />

Rating plate and extra rating plates<br />

Second rating plate, loose K31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Extra rating plate or rating plate<br />

with deviating rating plate data<br />

Extra rating plate with identification<br />

code<br />

Y80 • and<br />

identification<br />

code<br />

Y82 • and<br />

identification<br />

code<br />

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

For legend and footnotes, see page 3/55.<br />

3/54 Siemens D81.1 · 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!