20.09.2015 Views

Catalog

Old Catalog Motor 2006.pdf - Motology

Old Catalog Motor 2006.pdf - Motology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IEC Squirrel-Cage Motors<br />

Non-standard motors frame size 315 and above<br />

Dimensions<br />

■ Overview<br />

Overall dimensions<br />

L<br />

AD<br />

O<br />

G_D081_XX_00144<br />

H<br />

3<br />

AB<br />

Frame Type Number Dimensions<br />

size of poles L AD H AB<br />

315 1LA8 2 1380 570 315 680<br />

1LA8 4, 6, 8 1410 570 315 680<br />

1LA8 4, 6, 8 1) 1430 570 315 680<br />

1PQ8 2 1742 570 315 680<br />

1PQ8 4, 6, 8 1772 570 315 680<br />

1PQ8 4 1) 1792 570 315 680<br />

1LL8 2 1380 655 315 680<br />

1LL8 4, 6, 8 1410 655 315 680<br />

355 1LA8 2 1605 710 355 780<br />

1LA8 4, 6, 8 1635 710 355 780<br />

1LA8 4, 6, 8 1) 1700 710 355 780<br />

1PQ8 2 1971 690 355 780<br />

1PQ8 4, 6, 8 2001 690 355 780<br />

1PQ8 4, 6, 8 1) 2065 690 355 780<br />

1LL8 2 1605 840 355 780<br />

1LL8 4, 6, 8 1635 840 355 780<br />

Frame Type Number Dimensions<br />

size of poles L AD H AB<br />

400 1LA8 2 1795 865 400 860<br />

1LA8 4, 6, 8 1835 865 400 860<br />

1PQ8 2 2148 865 400 860<br />

1PQ8 4, 6, 8 2188 865 400 860<br />

1LL8 2 1793 865 400 860<br />

1LL8 4, 6, 8 1833 865 400 860<br />

450 1LA8 2 1955 900 450 980<br />

1LA8 4, 6, 8 1995 900 450 980<br />

1PQ8 2 2308 900 450 980<br />

1PQ8 4, 6, 8 2348 900 450 980<br />

1LL8 2 1953 900 450 980<br />

1LL8 4, 6, 8 1993 900 450 980<br />

For dimension "O", see "Introduction" under "Connection boxes".<br />

Notes on the dimensions<br />

7 Dimension drawings according to DIN EN 50347 and<br />

IEC 60072.<br />

7 Fits<br />

The shaft extensions specified in the dimension tables (DIN 748)<br />

and centering spigot diameters (DIN EN 50347) are machined<br />

with the following fits:<br />

Dimension designation ISO fit DIN ISO 286-2<br />

D, DA over 50 m6<br />

N over 250 h6<br />

F, FA h9<br />

The drilled holes of couplings and belt pulleys should have an<br />

ISO fit of at least H7.<br />

7 Dimension tolerances<br />

For the following dimensions, the permissible deviations are<br />

given below:<br />

Dimension designation Dimension Permitted<br />

deviation<br />

A, B over 500 to 750 ± 1.5<br />

over 750 to 1000 ± 2.0<br />

over 1000 ± 2.5<br />

M over 500 ± 1.0<br />

H over 250 – 1.0<br />

E, EA – 0.5<br />

Keyways and feather keyways (dimensions GA, GC, F and FA)<br />

are made in compliance with DIN 6885 Part 1.<br />

7 All dimensions are specified in mm.<br />

1)<br />

With bearings for increased cantilever forces: Dimensions available on<br />

request.<br />

Siemens D 81.1 · 2006<br />