IEC Squirrel-Cage Motors<br />

Explosion-proof motors<br />

Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or<br />

prot. against dust explosions - Cast-iron series 1LG6<br />

■ Selection and ordering data (continued)<br />

Order No.<br />

Locked-rotor<br />

torque<br />

Order No. supplements<br />

Locked-rotor<br />

current<br />

Breakdown<br />

torque<br />

with direct starting as multiple of rated<br />

torque current torque<br />

p Standard version<br />

† With no extra charge<br />

✓ With extra charge<br />

– Not possible<br />

Order other voltages with voltage code 9 in the penultimate position<br />

and the corresponding order code (see "Special versions"<br />

in the "Selection and ordering data" under "Voltages").<br />

Torque class<br />

Moment of inertia Noise<br />

Measuringsurface<br />

sound<br />

pressure level<br />

at 60 Hz<br />

T LR /T rated I LR /I rated T B /T rated CL J L pfA L WA<br />

kgm² dB(A) dB(A)<br />

2-pole, 3600 rpm at 60 Hz, temperature class F, IP55 degree of protection,<br />

for implementation in the North American market according to EPACT<br />

1LG6 183-2AAqq 2.7 7.9 3.7 16 0.086 72 85<br />

1LG6 206-2AAqq 2.7 7.8 3.7 16 0.15 75 88<br />

1LG6 207-2AAqq 2.8 7.8 3.7 16 0.18 75 88<br />

1LG6 223-2AAqq 2.8 8.3 3.6 16 0.27 74 87<br />

1LG6 228-2AAqq 3.3 8.7 3.7 16 0.32 74 87<br />

1LG6 253-2AAqq 2.7 7.5 3.2 16 0.47 75 88<br />

1LG6 258-2AAqq 2.8 8.4 3.5 16 0.57 79 92<br />

1LG6 280-2ABqq 2.8 7.9 3.4 13 0.83 77 90<br />

1LG6 283-2ABqq 2.9 8.3 3.4 13 1 77 90<br />

1LG6 288-2AAqq 3.1 8.5 3.6 16 1.16 77 90<br />

1LG6 310-2ABqq 2.6 7.5 3.1 13 1.4 81 94<br />

1LG6 313-2ABqq 3 8.3 3.3 13 1.6 81 94<br />

1LG6 316-2ABqq 3 8.4 3.5 13 2.1 81 94<br />

1LG6 317-2ABqq 3.2 8.6 3.4 13 2.5 81 94<br />

1LG6 318-2AAqq 4.1 10 3.9 16 2.74 83 96<br />

Sound pressure<br />

level at 60 Hz<br />

Motor type<br />

Penultimate position: Final position: Type of construction code<br />

Voltage code<br />

60 Hz Without flange With flange With standard flange With special flange<br />

460 VY 460 VD IM B3/6/7/8, IM B5, IM V3 IM V1 with IM B35 IM B14,<br />

1) 2) 1) 3) 4)<br />

IM V6 protective<br />

cover 1) 3) 5) IM V19 1) IM B34 IM B14, IM V19 1)<br />

(see "Introduction"<br />

for outputs at 60 Hz)<br />

1 6 0 1 4 6 2 7 3<br />

1LG618.-...qq † † p ✓ ✓ ✓ – – –<br />

1LG620.-...qq † † p ✓ ✓ ✓ – – –<br />

1LG622.-...qq † † p ✓ ✓ ✓ – – –<br />

1LG625.-...qq † † p ✓ ✓ ✓ – – –<br />

1LG628.-...qq † † p ✓ ✓ ✓ – – –<br />

1LG6310-...qq † † p ✓ ✓ ✓ – – –<br />

1LG6313-...qq<br />

1LG6316-...qq<br />

1LG6317-...qq<br />

1LG6318-...qq<br />

– † p 6) – ✓ 7) ✓ – – –<br />

Order other types of construction with type of construction code<br />

9 in the final position and the corresponding order code (see<br />

"Special versions" in the "Selection and ordering data" under<br />

"Types of construction").<br />

4<br />

1)<br />

2)<br />

3)<br />

The following applies for explosion-proof motors: In the case of the types<br />

of construction with shaft end down, the version "with protective cover" is<br />

required. For types of construction with shaft extension pointing upwards,<br />

a suitable cover must be implemented to prevent small parts from falling<br />

into the fan cover (see the standard IEC/EN 60079-0). The cover must not<br />

block the cooling air-flow.<br />

If motors 1LG6 183-... to 1LG6 318-... (motor series 1LG6 frame sizes<br />

180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6<br />

are fixed to the wall, it is recommended that the motor feet are supported.<br />

1LG6 220-... to 1LG6 318-... motors (motor series 1LG6 frame sizes 225 S<br />

to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5,<br />

whereby one can be rotated in accordance with IM V1 or IM V3. It is important<br />

to note that stress must not be applied perpendicular to the ring plane.<br />

4)<br />

5)<br />

6)<br />

7)<br />

Type of construction IM V3 is only possible using type of construction code<br />

9 and order code M1G.<br />

The "Second shaft extension" option, order code K16 is not possible.<br />

Type of construction IM V6 is only possible using type of construction code<br />

9 and order code M1E.<br />

2-pole motors in 60 Hz version available on request.<br />

Siemens D 81.1 · 2006<br />