IEC Squirrel-Cage Motors<br />

Explosion-proof motors<br />

Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or<br />

prot. against dust explosions - Aluminium series 1LA9<br />

4<br />

■ Selection and ordering data (continued)<br />

Rated output<br />

at 60 Hz<br />

Frame<br />

size<br />

Special versions according to ATEX<br />

Motor type Zone 2 VIK (includes Zone 2) 1) Zone 21 Zone 22<br />

✓ With extra charge<br />

– Not possible<br />

Operating values at rated output Order No. Price Weight<br />

Rated speed<br />

at 60 Hz<br />

Rated torque<br />

at 60 Hz<br />

EPACT with<br />

CC No. CC<br />

032A<br />

Nominal<br />

efficiency<br />

at 60 Hz<br />

Power factor<br />

at 60 Hz<br />

4/4-load<br />

Rated<br />

current<br />

at 460 V,<br />

60 Hz<br />

For order No. supplements<br />

for voltage, type<br />

of construction and<br />

explosion protection<br />

zones according to<br />

ATEX, see tables below<br />

P rated FS n rated T rated h rated cosj rated I rated m<br />

HP rpm Nm % A kg<br />

4-pole, 1800 rpm at 60 Hz, temperature class F, IP55 degree of protection,<br />

for implementation in the North American market according to EPACT<br />

0.08 56 M 1715 0.33 No 63 0.65 0.18 1LA9 050-4KAqq 3<br />

0.12 56 M 1725 0.5 No 64 0.6 0.29 1LA9 053-4KAqq 3.8<br />

0.16 63 M 1710 0.66 No 68 0.6 0.37 1LA9 060-4KAqq 4.1<br />

0.25 63 M 1705 1.1 No 66 0.63 0.54 1LA9 063-4KAqq 5.1<br />

0.33 71 M 1730 1.4 No 69 0.6 0.76 1LA9 070-4KAqq 6<br />

0.5 71 M 1725 2.1 No 70 0.68 0.98 1LA9 073-4KAqq 7.2<br />

0.75 80 M 1725 3.1 No 75.5 0.74 1.24 1LA9 080-4KAqq 9.8<br />

1 80 M 1720 4.1 Yes 82.5 0.75 1.59 1LA9 083-4KAqq 12.3<br />

1.5 90 S 1755 6.1 Yes 84 0.76 2.15 1LA9 090-4KAqq 15<br />

2 90 L 1775 14 Yes 84 0.76 2.95 1LA9 096-4KAqq 18<br />

3 100 L 1750 12 No 87.5 0.79 4 1LA9 106-4KAqq 25<br />

4 100 L 1750 16 No 87.5 0.79 5.5 1LA9 107-4KAqq 30<br />

5 112 M 1755 20 Yes 87.5 0.79 6.7 1LA9 113-4KAqq 37<br />

7.5 132 S 1760 30 Yes 89.5 0.81 9.5 1LA9 130-4KAqq 45<br />

10 132 M 1760 40 Yes 89.5 0.82 12.8 1LA9 133-4KAqq 60<br />

15 160 M 1765 61 Yes 91 0.85 17.9 1LA9 163-4KAqq 81<br />

20 160 L 1765 81 Yes 91 0.85 24.5 1LA9 166-4KAqq 107<br />

25 180 M 1770 101 Yes 92.4 0.83 30.5 1LA9 183-4WAqq 126<br />

30 180 L 1770 121 Yes 92.4 0.83 36 1LA9 186-4WAqq 146<br />

40 200 L 1770 161 Yes 93 0.86 47 1LA9 207-4WAqq 199<br />

Frame<br />

size<br />

Mains-fed<br />

operation<br />

Order code<br />

M72<br />

Converter-fed<br />

operation<br />

Order code<br />

M73<br />

Mains-fed<br />

operation<br />

Order code<br />

K30<br />

Converter-fed<br />

operation<br />

On request<br />

Mains-fed<br />

operation<br />

Order code<br />

M34<br />

Converter-fed<br />

operation<br />

Order code<br />

M38<br />

Mains-fed<br />

operation<br />

Order code<br />

M35<br />

1LA9 56 – – – – ✓ ✓ ✓ ✓<br />

63 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

71 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

80 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

90 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

100 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

112 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

132 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

160 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

180 – – – – ✓ ✓ ✓ ✓<br />

200 – – – – ✓ ✓ ✓ ✓<br />

IM B3<br />

type of<br />

construction<br />

approx.<br />

Converter-fed<br />

operation<br />

Order code<br />

M39<br />

The motors can also be used for 50 Hz "High Efficiency",<br />

see pages 4/48 to 4/53.<br />

1)<br />

If the marking EEx nA II is required in addition to VIK on the rating plate,<br />

this must be ordered using order code C27. The VIK version is not possible<br />

in combination with Zone 21 and 22.<br />

4/56 Siemens D 81.1 · 2006