IEC Squirrel-Cage Motors<br />

Explosion-proof motors<br />

Special versions<br />

4<br />

Special versions<br />

Additional<br />

Motor type frame size<br />

identification<br />

code -Z<br />

with order<br />

code and,<br />

if required,<br />

with plain<br />

text data 56 63 71 80 90 100 112 132 160 180 200 225 250 280 315<br />

Self-ventilated motors in Zone 2, 21, 22 with type of protection "n" or protection against dust explosions -<br />

Cast-iron series 1LA6 and 1LG4<br />

1LA6 (cast-iron) 1LG4 (cast-iron)<br />

Designs for Zones 2, 21 and 22 according to ATEX 1)<br />

Design for Zone 2 for mains-fed M72 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

to IEC/EN 60079-15<br />

operation Ex nA II T3, EEx nA II T3<br />

Design for Zone 2 for converter-fed M73 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Ex nA II T3, EEx nA II T3 to<br />

IEC/EN 60079-15 2) 3) 4)<br />

operation, reduced output<br />

Design for Zone 21, as well as M34 – – – – ✓ ✓ ✓ ✓ ✓ ✓<br />

Zone 22 for conducting dust (IP65)<br />

for mains-fed operation<br />

Design for Zone 21, as well as M38 – – – – ✓ ✓ ✓ ✓ ✓ ✓<br />

for converter-fed operation,<br />

derating 2) 4)<br />

Zone 22 for conducting dust (IP65)<br />

Design for Zone 22 for non-conducting<br />

M35 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

dust (IP55) for mains-fed<br />

operation<br />

Design for Zone 22 for non-conducting<br />

M39 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

dust (IP55) for converter-<br />

fed operation, derating 2) 4)<br />

VIK design (comprises Zone 2 K30 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

EEx nA II marking on rating<br />

plate) 5)<br />

for mains-fed operation, without<br />

EEx nA II on VIK rating plate C27 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Alternative converter<br />

(SIMOVERT MASTERDRIVES,<br />

SINAMICS G110 or ET 200S FC)<br />

Y68 • and<br />

converter<br />

type ….<br />

† † † † † † † † † †<br />

Motor protection<br />

With PTC thermistors for alarm A10 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

in Zones 2, 21, 22<br />

for converter-fed operation<br />

Motor protection with PTC thermistors<br />

A11 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

with 3 embedded tem-<br />

perature sensors for tripping<br />

Motor protection with PTC thermistors<br />

A12 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

perature sensors for tripping and<br />

alarm 6)<br />

with 6 embedded tem-<br />

Motor temperature detection with A23 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

KTY 84-130<br />

embedded temperature sensor<br />

Motor temperature detection with A25 – – – – ✓ ✓ ✓ ✓ ✓ ✓<br />

2 x KTY 84-130<br />

embedded temperature sensors<br />

Installation of 3 PT 100 resistance A60 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers 6)<br />

Installation of 6 PT 100 resistance A61 – – – – ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers in stator winding 6)<br />

Installation of 2 PT 100 screw-in<br />

resistance thermometers (basic<br />

circuit) for rolling-contact bearings<br />

6) 7)<br />

A72 – – – – ✓ ✓ ✓ 8) ✓ ✓ ✓<br />

Installation of 2 PT 100 double A78 – – – – ✓ ✓ ✓ 8) ✓ ✓ ✓<br />

(3-wire circuit) for rolling-contact<br />

bearings 6) 7)<br />

screw-in resistance thermometers<br />

Installation of 2 PT 100 screw-in<br />

resistance thermometers (3-wire<br />

circuit) for rolling-contact bearings<br />

6) 7)<br />

A80 – – – – ✓ ✓ ✓ 8) ✓ ✓ ✓<br />

For legend and footnotes, see page 4/114.<br />

4/110 Siemens D 81.1 · 2006