20.09.2015 Views

Catalog

Old Catalog Motor 2006.pdf - Motology

Old Catalog Motor 2006.pdf - Motology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IEC Squirrel-Cage Motors<br />

Motors operating with frequency converters<br />

Special versions<br />

5<br />

Options<br />

Options or order codes (supplement -Z is required)<br />

Special versions<br />

Additional<br />

Motor type frame size<br />

identification<br />

code -Z<br />

with order<br />

code and<br />

plain text<br />

if required<br />

56 63 71 80 90 100 112 132 160 180 200 225 250 280 315<br />

Self-ventilated motors with special insulation for voltages up to 690 V - Aluminium series 1LA7 and 1LA5<br />

1LA7 (aluminium) 1LA5 (aluminium)<br />

Motor protection<br />

Motor protection with PTC A11 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

temperature sensors for tripping<br />

thermistors with 3 embedded<br />

Motor protection with PTC A12 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

temperature sensors for tripping<br />

and alarm 1)<br />

thermistors with 6 embedded<br />

Motor temperature detection A23 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

sensor KTY 84-130<br />

with embedded temperature<br />

3 temperature detectors for A31 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

tripping 1)<br />

Installation of 3 PT 100 resistance<br />

A60 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

thermometers 1) Motor connection and connection boxes<br />

Connection box on RHS K09 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Connection box on LHS K10 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Cable entry, standard configuration<br />

K54 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

Rotation of the connection box K83 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

through 90°, entry from<br />

DE (AS)<br />

Rotation of the connection box K84 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

through 90°, entry from<br />

NDE (BS)<br />

Rotation of connection box K85 † † † † ✓ ✓ ✓<br />

through 180°<br />

Next larger connection box L00 – – – – ✓ ✓ ✓<br />

External earthing L13 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

3 cables protruding,<br />

L44 O. O. O. O. O. O. O.<br />

0.5 m long 2) R. R. R. R. R. R. R.<br />

3 cables protruding,<br />

L45 O. R. O. R. O. R. O. R. O. R. O. R. O. R.<br />

1.5 m long 2)<br />

6 cables protruding,<br />

L47 O. R. O. R. O. R. O. R. O. R. O. R. O. R.<br />

0.5 m long 2)<br />

6 cables protruding,<br />

L48 O. R. O. R. O. R. O. R. O. R. O. R. O. R.<br />

1.5 m long 2)<br />

6 cables protruding,<br />

L49 – – – – O. R. O. R. O. R.<br />

3 m long 2)<br />

Connection box on NDE (BS) M64 ✓ ✓ ✓ ✓ ✓ ✓ ✓<br />

For legend and footnotes, see page 5/26.<br />

5/22 Siemens D 81.1 · 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!