IEC Squirrel-Cage Motors<br />

Explosion-proof motors<br />

Self-ventilated, in Zone 1 with type of protection "e"<br />

Aluminium series 1MA7<br />

4<br />

■ Selection and ordering data<br />

Rated output<br />

at<br />

50 Hz 60 Hz<br />

Temperature<br />

class<br />

Frame<br />

size<br />

Operating values at rated output Order No. Price Weight<br />

Rated<br />

speed<br />

at 50 Hz<br />

Rated<br />

torque<br />

at 50 Hz<br />

Efficiency<br />

at 50 Hz<br />

Power<br />

factor<br />

at 50 Hz<br />

Rated<br />

current at<br />

380 ... 420 V,<br />

50 Hz<br />

For Order No.<br />

supplements for<br />

voltage and<br />

type of construction,<br />

see table below<br />

P rated P rated FS n rated T rated h rated cosj rated I rated m<br />

kW kW rpm Nm % A kg<br />

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class F, IP55 degree of protection,<br />

temperature classes T1 to T3<br />

0.18 0.18 T1,T2,T3 63 M 2810 0.61 66 0.74 0.55 1MA7 060-2BAqq 3.9<br />

0.25 0.25 T1,T2,T3 63 M 2800 0.85 68 0.81 0.7 1MA7 063-2BAqq 4.5<br />

0.37 0.37 T1,T2,T3 71 M 2825 1.3 73 0.8 0.93 1MA7 070-2BAqq 5.4<br />

0.55 0.55 T1,T2,T3 71 M 2785 1.9 72 0.80 1.4 1MA7 073-2BAqq 7<br />

0.75 0.75 T1,T2,T3 80 M 2845 2.5 73 0.85 1.81 1MA7 080-2BAqq 8.6<br />

1.1 1.1 T1,T2,T3 80 M 2855 3.7 79 0.85 2.5 1MA7 083-2BAqq 10.3<br />

1.3 1.3 T1,T2,T3 90 S 2850 4.4 78 0.88 2.9 1MA7 090-2BAqq 13.3<br />

1.85 1.85 T1,T2,T3 90 L 2860 6.2 81 0.88 3.95 1MA7 096-2BAqq 16.1<br />

2.5 2.5 T1,T2,T3 100 L 2865 8.3 82 0.87 5.3 1MA7 106-2BAqq 21<br />

3.3 3.3 T1,T2,T3 112 M 2875 11 84 0.89 6.7 1MA7 113-2BBqq 27<br />

4.6 4.6 T1,T2,T3 132 S 2920 15 83 0.9 9.2 1MA7 130-2BBqq 53<br />

5.5 5.5 T3 132 S 2925 18 86 0.92 10.6 1MA7 131-2BBqq 1) 44<br />

7.5 7.5 T3 160 M 2945 24 87.5 0.9 14.3 1MA7 163-2BBqq 1) 67<br />

10 10 T3 160 M 2940 33 88.5 0.92 18.6 1MA7 164-2BBqq 1) 72<br />

12.5 12.5 T3 160 L 2940 41 89 0.93 23 1MA7 166-2BBqq 1) 82<br />

IM B3<br />

type of<br />

construction<br />

approx.<br />

Rated output<br />

at<br />

50 Hz 60 Hz<br />

Temperature<br />

class<br />

Frame<br />

size<br />

p Standard version<br />

† With no extra charge<br />

✓ With extra charge<br />

– Not possible<br />

Order other voltages with voltage code 9 in the penultimate position<br />

and the corresponding order code (see "Special versions"<br />

in the "Selection and ordering data" under "Voltages").<br />

Operating values at rated output Order No. Price Weight<br />

Rated<br />

speed<br />

at 50 Hz<br />

Rated<br />

torque<br />

at 50 Hz<br />

Efficiency<br />

at 50 Hz<br />

Power<br />

factor<br />

at 50 Hz<br />

Rated<br />

current at<br />

380 ... 420 V,<br />

50 Hz<br />

For Order No.<br />

supplements for<br />

voltage and<br />

type of construction,<br />

see table below<br />

P rated P rated FS n rated T rated h rated cosj rated I rated m<br />

kW kW rpm Nm % A kg<br />

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class F, IP55 degree of protection,<br />

temperature classes T1 and T2, with double rating plate (T1/T2 and T3)<br />

6.5 6.5 T1,T2 132 S 2900 21 85 0.93 12.5 1MA7 131-2BBqq 1) 44<br />

9.5 9.5 T1,T2 160 M 2920 31 87 0.91 18.1 1MA7 163-2BBqq 1) 67<br />

13 13 T1,T2 160 M 2910 43 87.5 0.92 24.5 1MA7 164-2BBqq 1) 2) 72<br />

16 16 T1,T2 160 L 2910 53 87 0.93 30 1MA7 166-2BBqq 1) 2) 82<br />

Order No. supplements<br />

Motor type Penultimate position: Voltage code Final position:<br />

Type of construction code<br />

50 Hz Without With flange<br />

flange<br />

230 VD/400 VY 400 VD/690 VY 500 VY 500 VD IM B3/6/7/8,<br />

For delta connection, overload protection with<br />

IM V6 3) IM B5,<br />

IM V3 3)<br />

phase-failure protection must be provided.<br />

IM B3<br />

type of<br />

construction<br />

approx.<br />

With standard flange With special<br />

flange<br />

IM V1 IM B35 IM B14,<br />

with protective<br />

IM V19 3) IM B34 IM B14<br />

IM V19 3)<br />

cover 3) 4)<br />

1 6 3 5 0 1 4 6 2 7 3<br />

1MA7 06 . - . . . qq † – † – p ✓ ✓ ✓ ✓ ✓ ✓<br />

1MA7 07 . - . . . qq † † † – p ✓ ✓ ✓ ✓ ✓ ✓<br />

1MA7 08 . - . . . qq † † † – p ✓ ✓ ✓ ✓ ✓ ✓<br />

1MA7 09 . - . . . qq † † † – p ✓ ✓ ✓ ✓ ✓ ✓<br />

1MA7 10 . - . . . qq † † † † p ✓ ✓ ✓ ✓ ✓ ✓<br />

1MA7 11 . - . . . qq † † † † p ✓ ✓ ✓ ✓ ✓ ✓<br />

1MA7 13 . - . . . qq † † † † p ✓ ✓ ✓ ✓ ✓ ✓<br />

1MA7 16 . - . . . qq † † † † p ✓ ✓ ✓ ✓ ✓ ✓<br />

Order other types of construction with type of construction code<br />

9 in the final position and the corresponding order code (see<br />

"Special versions" in the "Selection and ordering data" under<br />

"Types of construction").<br />

For footnotes, see page 4/13.<br />

4/12 Siemens D 81.1 · 2006