SATRONIC - Control boxes for oil burners
SATRONIC - Control boxes for oil burners
SATRONIC - Control boxes for oil burners
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>SATRONIC</strong> - <strong>Control</strong> <strong>boxes</strong> <strong>for</strong> gas-<strong>burners</strong><br />
Type Notes<br />
model<br />
appr. <strong>for</strong> direct-air-heaters<br />
appr. <strong>for</strong> <strong>oil</strong>- and gas operation<br />
action on<br />
flame failure<br />
direct lockout<br />
re-cycle<br />
with built in remote reset<br />
with air-damper control<br />
ignition spark supervising<br />
waiting time at start position<br />
pre-purge (sec.)<br />
pre-ignition (sec.)<br />
pilot valve<br />
safety<br />
time<br />
(sec.)<br />
start valve<br />
valve 1<br />
flame failure<br />
post-ignition (sec.)<br />
TFI 812.2 10 x x - 10 10 1 - 20 x x x x x <strong>for</strong> atmosph. gas <strong>burners</strong><br />
TFI 812.2 5 x x - 15 5 1 - 20 x x x x x <strong>for</strong> atmosph. gas <strong>burners</strong><br />
TFI 812 B 10 x 12 - - 10 1 20 x x x x version <strong>for</strong> the UK, 240 V<br />
TFI 812 B 5 x 12 - - 5 1 20 x x x x version <strong>for</strong> the UK, 240 V<br />
1<br />
delay <strong>for</strong> valve 1<br />
delay <strong>for</strong> valve 2<br />
86 x 60 x 63<br />
size (box<br />
with base)<br />
L x W x H<br />
86 x 60 x 91<br />
102 x 102 x 120<br />
Ionisation<br />
UVZ 780 blue<br />
possible<br />
flame<br />
sensors<br />
UVZ 780 white<br />
UVZ 780 red<br />
UVZE/FZE 780<br />
IRD 820<br />
IRD 920<br />
IRD 1020<br />
115e/08/94<br />
MMI 810 32 x 9 30 3,5 2 1 1,5 12 x x x x x version <strong>for</strong> Italy<br />
MMI 810 33 x x x 9 30 3,5 3 1 2,5 12 x x x x x<br />
MMI 810 35 x x x 9 30 3,5 5 1 4,5 12 x x x x x<br />
MMI 810 45 x 5 40 - 5 1 4,5 12 x x x x x version <strong>for</strong> the UK, 240 V<br />
MMI 810 310 x 9 30 3,5 10 1 9,5 15 x x<br />
MMI 810 40-34 x x - 40 - 5 5 1 4.5 10 x x version <strong>for</strong> the Netherlands<br />
MMI 811 35 x 9 30 3,5 5 1 4,5 12 x x x x x<br />
MMI 811 63 x 5 60 3,5 3 1 2,5 7 x x x x x version <strong>for</strong> the Netherlands<br />
MMI 812 33 x x x 5 63 3,5 3 1 2,5 7 x x x x x<br />
MMI 812 63 x 5 95 6,4 3 1 2,5 - x x x x version <strong>for</strong> the Netherlands<br />
MMI 815 5 x 17 - 4 - - 5 1 4 - 15 x x x x x <strong>for</strong> atmosph. gas <strong>burners</strong><br />
MMI 815 10 x 17 - 4 - - 10 1 9 - 15 x x x x x <strong>for</strong> atmosph. gas <strong>burners</strong><br />
MMI 816 x 15 - 3 10 - 10 1 10 7 - x x version <strong>for</strong> the Netherlands<br />
MMG 810 32 x x x x 9 40 2 2 1 1 7 x x x x x x version <strong>for</strong> Italy<br />
MMG 810 33 x x x x 9 40 2 3 1 2 7 x x x x x x<br />
MMG 810 45 x x 5 40 - 5 1 4,5 10 x x x x x x version <strong>for</strong> the UK, 240 V<br />
MMG 811 33 x 5 30 3,5 3 1 2,5 10 x x x x x x version <strong>for</strong> Switzerland,<br />
with safty valve<br />
MMG 811 63 x 5 60 3,5 3 1 2,5 7 x x x x x x version <strong>for</strong> the Netherlands