06.12.2012 Views

SATRONIC - Control boxes for oil burners

SATRONIC - Control boxes for oil burners

SATRONIC - Control boxes for oil burners

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SOVE 930<br />

WIRING DIAGRAM SOVE 930<br />

Ph<br />

release to the control box<br />

6 A T max.<br />

safety<br />

thermostat<br />

control<br />

thermostat<br />

green-yellow<br />

brown<br />

blue<br />

N<br />

black<br />

2<br />

3<br />

4<br />

3<br />

<strong>Control</strong><br />

circuit<br />

release thermostat<br />

temperature sensor<br />

heating element<br />

STARTPROCESS SOVE 930 AT A THROUGHPUT OF 2.5 KG/H<br />

Place of measurment: in the <strong>oil</strong> between shaft and nozzle filter – Test fluid: Shell Calibration fluid – Voltage: 230 V<br />

temperature (° C)<br />

65<br />

60<br />

55<br />

50<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

valve opens<br />

release temperature in the <strong>oil</strong> prior nozzlefilter,<br />

pre-purge of 12 secs. starts<br />

0 10 20 30 40 50 60 70 80 90 100 110 120 time (sec.)<br />

SOVE 930, OIL OUTLET TEMPERATURE AS A FUNCTION OF THROUGHPUT AND POWER<br />

Place of measurment: in the <strong>oil</strong> between shaft and nozzle filter – Test fluid: Shell Calibration fluid – Voltage: 230 V<br />

temperature (° C)<br />

70<br />

65<br />

60<br />

55<br />

50<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

0 0.5 1.0<br />

1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0<br />

throughput quantity (kg/h)<br />

Variation of the voltage between 205 V and 255 V changes the temperature<br />

related to the throughput quantity only <strong>for</strong> max. ± 1° C.