23.10.2016 Views

BB ELECTRONICS CATALOG (2010)

Catalog from B&B Electronis (2010)

Catalog from B&B Electronis (2010)

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Wireless<br />

Serial Radio<br />

Modems<br />

Modular I/O<br />

Antennas<br />

WiFi/802.11<br />

Ethernet<br />

Bridges<br />

Cellular<br />

Routers<br />

Zlinx ® Product Family of Wireless I/O & Radio Modems<br />

Wireless Success is Easier Than Ever!<br />

MODBUS<br />

Common Specifications<br />

• IP30 Ingress Protection Rating<br />

• Long (900 MHz) and (2.4 GHz) Short Range Radio Options<br />

• Versatile Power: 10 to 40 VDC and/or 24VAC<br />

• Wide Temperature Range: -40 to 85°C (selectable)<br />

•AES Encryption: (256 bit) 900 MHz; (128 bit) 2.4 GHz<br />

• Over-the-Air data rates: LR- 9.6k/115.2k(selectable);<br />

SR-250K(fixed)<br />

WIDE TEMP<br />

WIRELESS<br />

IP30, DIN Mount, Industrial Wireless I/O<br />

Wireless I/O - Cable Replacement & Modbus<br />

Connectivity Solutions<br />

Zlinx I/O Specific Features<br />

• Peer-to-peer mirrored I/O mapping<br />

• High performance, low latency response rates - down to 15mS<br />

• Supports field calibration for precision applications<br />

• User defined fail-safe output states ensures safe operation<br />

SECURE<br />

• Modbus Compatible<br />

• Frequency: ISM Band 902 to 928 MHz. 2.4 to 2.4385 GHz<br />

• Modulation: FSK (Frequency Shift Keying)<br />

• Transmit Power: 900 MHz: 1 mW to 1W; 2.4 GHz: 10mW<br />

to 63 mW<br />

• Receiver Sensitivity: 900 MHz: 100 dbm@115.2K,<br />

-110 dbm@9.6K; 2.4 GHz: -102 dBm<br />

Zlinx Wireless I/O modules monitor and control analog, digital and RTD temperature devices remotely. The wireless I/O modules<br />

are available in base I/O and modular expansion I/O configurations. Base I/O modules have built-in radio with limited I/O<br />

combination. Expansion modules have different I/Os types and combinations for cost-effective system integration. Up to 6 expansion<br />

modules can be added to a base I/O module.<br />

Base I/O Modules<br />

Model No. Digital Digital Analog Analog RF Range with RF Range with RF Range Price<br />

Inputs Outputs Inputs Outputs Supplied Antenna Supplied Antenna with High Gain<br />

(indoor max.) (outdoor max.) Antenna (outdoor max.)<br />

2.4 GHz – Short Range Models<br />

ZZ24D-NA-SR 2 2 (PNP) 2 2 300 ft 1 mi 10 mi $419.00<br />

ZZ24D-NB-SR 4 4 (PNP) 300 ft 1 mi 10 mi 349.00<br />

ZZ24D-NC-SR 2 2 (NPN) 2 2 300 ft 1 mi 10 mi 419.00<br />

ZZ24D-ND-SR 4 4 (NPN) 300 ft 1 mi 10 mi 349.00<br />

900 MHz – Long Range Models<br />

ZZ9D-NA-SR 2 2 (PNP) 2 2 3,000 ft 14 mi 40 mi $649.00<br />

ZZ9D-NB-SR 4 4 (PNP) 3,000 ft 14 mi 40 mi 599.00<br />

ZZ9D-NC-SR 2 2 (NPN) 2 2 3,000 ft 14 mi 40 mi 649.00<br />

ZZ9D-ND-SR 4 4 (NPN) 3,000 ft 14 mi 40 mi 599.00<br />

Note 1. The specified RF ranges are design criteria under ideal conditions. Actual range may vary depending on the environmental conditions.<br />

Note 2. Sinking Analog Output – Requires external power supply<br />

Note 3. ZZPROG1-USB Programming kit required. See page 83.<br />

Digital Inputs (DI) 0-48 VDC NPN (sinking)<br />

The Zlinx I/O system (base + expansion modules) can be configured<br />

in 2 ways:<br />

1 Peer-to-Peer (P2P) I/O cable replacement: Two identical wireless<br />

I/O systems of same frequency and I/O count can be configured as a<br />

wire replacement, Peer-to-Peer system. Analog and digital input<br />

count in one system must equal to the analog and digital output<br />

count in the other. One system must be configured as a P2P Master<br />

and the other as a P2P slave. It does not matter which system is<br />

configured as master. The inputs at one end are wirelessly mapped to<br />

the corresponding outputs at the other end.<br />

Typical applications: Wireless control of remote analog and digital<br />

devices from a PLC/SCADA I/O. Refer to the “Remote Pump Station<br />

Control” example application diagram on page 81.<br />

2 Modbus I/O: Analog, digital and temperature I/Os from up to 247<br />

I/O systems can be wirelessly connected to a Modbus RTU master<br />

such as a PLC or SCADA or an HMI through a Serial Radio Modem.<br />

Point-to-Multi-point configurations are possible.<br />

Typical applications: Remote wireless control of remote analog and<br />

digital devices from a PLC/SCADA I/O. Refer to the ‘Remote<br />

Material Handling Systems’ example application diagram on pages 81.<br />

Expansion I/O Modules<br />

BUILT<br />

O.E.M.<br />

F O R<br />

Y O U<br />

See Page 145<br />

Digital Outputs (DO) 10-48 VDC NPN, PNP, Relays<br />

Analog Inputs (AI) 4-20 mA, 0-20 mA or 0-10 VDC Selectable in software<br />

Analog Outputs (AO) 4-20 mA, 0-20 mA or 0-10 VDC Selectable in software<br />

RTD Temp. Inputs (AI) PT100, PT1000, CU10 Selectable in software<br />

Model No. Digital Digital Analog Analog Price<br />

Inputs Outputs Inputs Outputs<br />

ZZ-8DI-DC 8 $195.00<br />

ZZ-8DO-T 8 (PNP) 195.00<br />

ZZ-8DO-T1 8 (NPN) 195.00<br />

ZZ-4DI4DO-DCT 4 4 (PNP) 195.00<br />

ZZ-4DI4DO-DCT-1 4 4 (NPN) 195.00<br />

ZZ-4AI 4 299.00<br />

ZZ-4AO 4* 299.00<br />

ZZ-4AO-2 4** 299.00<br />

ZZ-2AI2AO 2 2 299.00<br />

ZZ-8DO-R 8 (Relay) 229.00<br />

ZZ-4RTD1 4 345.00<br />

* Sinking Analog Output – Requires external power supply<br />

** Sourcing Analog Output – No external power supply necessary<br />

82<br />

www.bb-elec.com<br />

815.433.5100